SERVICE PROCEDURES REQUIRING MAJOR DISASSEMBLY
SERVICE MANUAL NUMBER 28
90-863160 MAY 2000 Page 4B-27
3. Clean bellows mounting flange on gimbal housing with sandpaper and wipe clean with
lacquer thinner.
76662
a
a-Mounting Flange
WARNING
Be sure to read and follow package label direction when using bellows adhesive.
4. Apply bellows adhesive to inside diameter of bellows end that will be attached to gimbal
housing. Bellows adhesive IS NOT needed on the other end that connects to the bell
housing. Allow to dry until adhesive is no longer tacky (approximately 10 minutes) before
installing.
50383
a
a-Inside Diameter of Bellows End
IMPORTANT: TOP mark on U-joint bellows must be facing upward when installing
bellows.
50383
b
a
a-TOP Mark
b-Bead