Service manual
SERVICE PROCEDURES REQUIRING MAJOR DISASSEMBLY SERVICE MANUAL NUMBER 28
Page 4B-26 90-863160 MAY 2000
Gimbal Housing Servicing
U-joint Bellows Replacement
1. Remove U-joint bellows from gimbal housing.
50383
a
b
a-U-joint Bellows
b-Hose Clamp
2. If reusing bellows, remove old adhesive from U-joint bellows using lacquer thinner.
50383
a
a-U-joint Bellows
INDEX