Service manual
SERVICE PROCEDURES REQUIRING MINOR DISASSEMBLY SERVICE MANUAL NUMBER 28
Page 4A-24 90-863160 MAY 2000
2. Apply Perfect Seal to flanged nut threads. Secure shift cable to bell housing. Hold shift
cable retaining nut with wrench and torque flanged nut to 65 lb-in. (7 Nm).
50327
a
b
c
d
e
a-Shift Cable
b-Flanged Nut
c-Shift Cable Retaining Nut
d-Seal Washer (Hidden by Nut)
e-Core Wire
3. Install shift cable wrapping approximately 2” from gimbal housing.
76639
a
a-Shift Cable Wrapping
CAUTION
Water leakage may result if clamp is not installed properly. Check that bellows end
is not flattened out when crimping in the followIng step.
INDEX