Seal Removal
1. Pry water passage seal out with a suitable tool.
72450
a
a-Water Passage Seal
Seal Installation
1. Lightly coat outer diameter of seal with 3-M Adhesive and install in speedometer water
passage bore. Ensure top edge of seal is flush with gear housing surface.
72449
a
a-Seal Flush with Edge of Water Tube Bore