User's Guide Part 2
PureWave Quantum 6600 User Guide v2.1
Page 93
Overwriting the configuration file can have serious consequences. The User must proceed
with care.
Figure 86: Configuration Import Settings
The procedure to import a file to the Base Station:
(1) Select the filename to import into the running configuration from the drop down menu of the
Import Filename.
(2) If the User enables the Overwrite field, then this will replace the existing CPE configuration data
with the imported data. This will only work with files created with the export CPE option. Trying
to load other files with the overwrite option set will result in an error message.
(3) If the User does not enable the Overwrite field, then the imported data will be merged with the
existing configuration.
(4) The User must then press the Perform Command Menu Option.
At the Main Web GUI Interface Screen select the Configuration Tab, then configuration Main Menu
Option and then the write Main Menu Sub-Element. This will display window to write a configuration
The Import command can take several minutes to complete. Please wait until this process is
completed before going on to make any other configuration changes.