User's Guide Part 2
PureWave Quantum 6600 User Guide v2.1
Page 77
Figure 67 System Handover Trigger Setting
neighbor. This is the place to configure information about neighbor base stations (Figure 68).
This is required for handover operation. This can be left unconfigured if no handover is required.
For each neighbor, following needs to be configured:
a. BS id: This is the BSID of neighbor bs. Use upper case letters only. BSID of the
neighboring base stations should have same operator id as the serving base station., i.e.
the upper 6 bytes should be same.
o IP Address: This is the IP address of the neighbor base station.
o Preamble Index: This is the preamble-index of the neighbor base station.
o BS Index: This is a user defined number in the range of 1-254. The index of 255 has a
special meaning. When this index is set to 255 then the neighbor will be considered as a
non-Purewave base station, and Purewave base station will unconditionally accept the
handover request. No backbone communication will take place.
o BS Frequency: This is the frequency of the neighbor base station in KHz.