User's Guide Part 2

PureWave Quantum 6600 User Guide v2.1
Page 76
o ASN-Gateway Vendor ID. This User has the option to select and store the vendor of the
ASN Gateway. The current options are Wichorus and Cisco.
o ASN-Gateway NWG Version. This User has the option to select and store the current
firmware version of the ASN Gateway. The current options are v1.2 and v1.3.
Base-Station Settings
o Group-id. This is a free format text field.
o Group-descr. This is a free format text field.
o Mode. This defines the mode of operation for the Base Station. The default option is
standalone-local and the available options are asn-gateway and standalone-local.
External Radius Server Settings
o Radius Server IP Address. If the Base Station has been configured to use an external
Radius Server, then its IP address would be provided here.
o Radius Server Port Number. This is the Port Number that the Base Station use to
communicate with the Radius Server.
o Secret. This is the radius "secret" that is shared between the Base Station and the
Radius Server.
The system, base-station menu option has two further sub-elements, handover and neighbor.
handover. This is where triggers are set for handover operation (see Figure 67). By default,
there are no triggers. For handover operation at least two triggers must be set, one for scanning
and one for handover. This information is incorporated into DCD message sent by the base
station. This may be left unconfigured if no handover is desired. For each trigger following needs
to be configured:
o Trigger Index: A user defined unique number between 1-8.
o Average Duration: Trigger averaging duration is the time measured in number of frames
over which the metric measurements are averaged.
o Trigger Type: This defines trigger metric, CINR or RSSI
o Trigger Function: This parameter specifies the function for the trigger type chosen
earlier. Select one from the dropdown menu.
o Trigger Action: This parameter specifies the action, scanning or handover, to take when
trigger criteria is met. Select from the dropdown menu.
o Trigger Value: This parameter specifies the value for corresponding to the trigger type
and function selected above.