User's Guide Part 1
PureWave Quantum 6600 User Guide v2.1
Page 42
Figure 22: Commit Option Successful
Unsaved configuration changes persist for only the current boot. If the Base station is
rebooted then those changes will be lost if the configuration has not been committed.
Several menus have two sets of parameters, these are defined as:
Configured Parameters. These are the most recently saved settings and are stored in the
system’s configuration database
State Parameters. These are the readings of the actual state from the Base Station. State
Parameters may be identical to Configured Parameters, or they may be committed but unsaved
parameters that differ from the Configured Parameters.
After a reboot, both sets of parameters will be identical.
The "Save Procedure" is to ensure that the running configuration is saved is:
(1) At the Main Web GUI Interface Screen, select the Configuration Tab, select the configuration
Main Menu Option then the write Main Menu Sub-Element. The User will have to click on the
Perform Command Menu Option to copy the running configuration to the startup (see figure
23).