User's Guide Part 1
PureWave Quantum 6600 User Guide v2.1
Page 37
Figure 15: The Web GUI Interface Screen in Edit Private Mode
At the Main Web GUI Interface Screen, select the Configuration Tab, select the configuration Main
Menu option and then Edit Private or Edit Exclusive. The User will now be in the Edit mode.
There are a number of key concepts that will be repeatedly used when the User is in the Edit mode and
thus making configuration changes. These key concepts form the six Command Menu Options when the
User is in the Edit mode. These are:
Changes. This prompts the User to accept the configuration changes that have been made.
Validate. This validates that the changes are valid and have been configured correctly.
Revert All. This will cancel (or revert) any changes that may have been made.
Commit. This will commit the changes to the running database.
Rollback. This will rollback any changes to a previously saved state.
Exit Transaction. This will exit the Edit mode.
When the User selects the Changes Command Menu Option then they are presented with the following
options:
If no configuration changes have been made, then a popup window appears stating "No
configuration changes have been made". The User simply selects the OK prompt to navigate
back to the Edit Mode.