Figure 9: Pole Mounting Plates
First mount the Base Station Mounting Bracket (Figure 8: Base Station Mounting Bracket) to the base
station using the provided hardware, as indicated in Table 4. When installing the base station mounting
bracket onto the base station, be sure to align it as shown in Figure 10. Note that the bracket is
designed for upright mounting of the base station; that is, mounting with the connectors facing down.
Tighten the bolts to a torque of 30 in-lbs.
Figure 10: Base Station Mounting Bracket Alignment
The base station bracket may be mounted to the base station ahead of time as it has a built-
in handle that facilitates its transportation and carrying the base station up a tower.
To improve the effectiveness of connector waterproofing and to optimize the base station’s
thermal performance, it is recommended that the base station be mounted in an upright
position, with the connectors at the bottom.
Note that the base station bracket is designed specifically to attach to the 6 recessed
mounting holes on the base station, and hence can be useful in a variety of mounting
scenarios. However, use of this bracket without the pole mounting plates designed
specifically to accompany it is at the sole discretion and responsibility of the customer.
Front Mounting Plate Rear Mounting Plate