Table 3: Base Station Connector Descriptions
Connector
Function
POWER
-48VDC power source inputs for the unit.
DC power connector: Fits Tyco P/N 796095-2 connector.
GND
This M5 screw provides a ground connection point to the base station. It is the installer’s
responsibility to ensure that the unit is professionally grounded and complies with all relevant
local codes.
GPS
N-type connector for mandatory external GPS antenna. 3.3V power on center pin.
ETH-1
This Gigabit Ethernet port serves as the data traffic backhaul Interface and also provides for in-
band management of the base station. Note that this port may be physically routed directly to
the operator’s network equipment, or it may be daisy-chained through additional PureWave
Quantum sectors by routing it to another unit’s ETH-2 port.
Cat-5 (RJ-45), Single-Mode Fiber (HartingPull/Han 3 A), and Multi-Mode (LC duplex) Fiber
options are available for the ETH-1 port.
ETH-2
This Gigabit Ethernet port serves as an incoming daisy-chain port from a neighboring sector,
and may be used for out-of-band management of the base station. It may also be used to
connect to an external device, such as a web camera. Daisy-chained traffic is aggregated and
passed through the ETH-1 port.
Cat-5 (RJ-45), Single-Mode Fiber (HartingPull/Han 3 A), and Multi-Mode (LC duplex) Fiber
options are available for the ETH-2 port.
CONSOLE
RJ-45 based RS-232 port for CLI control via a console.
Defaults settings are 38400, 8, None, 1, Xon/Xoff.Xoff
ANT 1-2
N-type Tx / Rx Antenna Ports.