Product Manual

Table Of Contents
Recoil Starter Removal
1.
Remove the three screws that secure the air box to the engine, and remove the air box or position it out of the way. Refer
to Section 3C Air Box Removal.
NOTE: Due to the routing of the crankcase breather hose behind the throttle body, it is easiest to not fully remove the air
box, if no other components are being removed.
2. Remove the three screws securing the recoil starter assembly to the engine.
62950
Shown with air box removed
3. Pull the neutral interlock cable to disengage the neutral interlock cable from the recoil housing.
4.
Lift the neutral interlock cable up and remove the neutral interlock cable tension spring from the recoil housing.
a - Neutral interlock cable tension
spring
b - Neutral interlock cable
5. Remove the recoil starter assembly.
Recoil Starter Disassembly
!
WARNING
Uncontrolled release of the rewind spring can cause serious injury. Wear eye protection when servicing the rewind starter in
case the spring uncoils.
1. Remove the handle cap from the recoil handle.
2.
Cut or untie the recoil rope from the recoil handle.
3. Slowly allow the sheave to unwind completely.
4. Rotate the sheave clockwise to disengage the recoil spring from the sheave.
a
b
9696
Recoil Starter
Page 8A-6 © 2018 Mercury Marine 90-8M0125265 eng NOVEMBER 2017