TSD402 Intruder Alarm Control Panel & Speech Dialler UNSET 1 2 BELL TEST WALK TES T 3 4 5 6 USE R CODE 1 CHI ME USER CODE 2 7 8 9 HOME AREA DIALLER E VENT LOG HOME 0 AWAY TSD402 User Manual
Contents Overview Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Control Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Speech Dialler Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Operator Controls and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TSD402 User Manual Overview Overview Introduction The TSD402 is a 5 zone (+ Final Exit) control panel with an integral Speech Dialler. It is ideally suited for domestic and small commercial installations which require additional security through the communication of audio alarm messages over the telephone line. Control Panel Operation Operation and programming is carried out from the tactile rubber keypad on the control panel in conjunction with the 16 character Liquid Crystal Display (LCD).
Overview TSD402 User Manual Speech Dialler Operation The speech dialler may be configured by the engineer to trigger on FIRE, P.A. or ALARM activations for both the Away set and Home set. In addition to alarm triggers provided internally from the control panel, there are 3 auxiliary inputs which may be used by other devices to trigger the speech dialler independently from that of the control panel. Telephone Numbers - The TSD402 stores up to three different telephone numbers.
TSD402 User Manual Overview Acknowledgement Options - The TSD402 may be programmed to stop dialling after the first call has been acknowledged or when two, or three have been acknowledged. The acknowledgement may also be disabled altogether, when the speech dialler is used in this mode it dials the first telephone number and providing the call is answered it plays the message and shuts down. If the call is not answered it dials the second telephone number.
Operating the System TSD402 User Manual Operating the System Full Setting the System (AWAY) Before attempting to fully set the system, the risk of false alarms can be reduced by ensuring that all detectors are unobstructed and any doors, windows etc. are properly secured. Full Set (AWAY) UNSET Enter first two digits of passcode then ] (e.g.
TSD402 User Manual Operating the System Part-Setting the System (HOME) The system may have been programmed to allow you to have part of the system `set' while other areas are `off'. Before attempting to part-set the system, the risk of false alarms can be reduced by ensuring that all detectors are unobstructed and any doors, windows etc. are properly secured. Part-Set (HOME) UNSET Enter first two digits of passcode then [ (e.g.
Operating the System TSD402 User Manual Setting with a Zone Open If an attempt is made to set or part-set the system with one or more zones open, e.g., a door left open or detector still active etc. The sounder will give an interrupted tone and the display will indicate the zone circuits that are in fault. Setting with Zones Open UNSET Enter first two digits of passcode then ] (e.g.
TSD402 User Manual Operating the System Enter via the prescribed entry route. The entry tone will start and the display shows the remaining time. ENTER CODE 025 Enter your passcode (e.g., 5 6 7 8) User Reset Engineer Reset Remote Reset CCT AL. 1 CCT AL. 1 CCT AL. 1 The display shows the zone that caused the alarm CALL ENGINEER CALL ENGINEER Enter your passcode (e.g., 5 6 7 8) The display shows the zone that caused the alarm and the Call Engineer message.
Operating the System TSD402 User Manual Changing Chime Zones When a zone is programmed as `Chime' it will generate a two-tone sound from the internal sounders when activated during the unset or part-set condition. This may be used as a courtesy warning for a door being opened e.g., front or back door, or shop entrance door etc.
TSD402 User Manual User Options User Options Introduction The `User 1' passcode has the option to access the `User Options' menu, this menu allows the user to test the system, change passcodes, change Home area configuration, view the event log and program the speech dialler. To aid user programming, a brief description of each menu function has been printed underneath each number key. The figure below shows the structure of the `User Options' menu.
User Options TSD402 User Manual Bell Test (key 1 ) This option allows the internal sounders, external sounders and external strobe lights to be tested by user 1. When selected each device will operate in sequence for 9 seconds, as each device is switched on the display will count down the remaining on time. Bell Test UNSET Enter first 3 digits of Passcode then [ (e.g., 5 6 7 [) USER OPTION Press 1 for Bell Test SnDr BELL STB- 9 Internal Sounders on Press [ to advance test or ] to abandon tests.
TSD402 User Manual User Options Walk Test (key 2 ) The Walk Test option allows user 1 to test the function of all detection zones without causing an alarm. As each zone is activated the zone number is displayed and the internal sounders generate a two-tone sound. When the zone is deactivated the sounder will stop, but the display will latch the activated zone. Walk Test UNSET Enter first 3 digits of Passcode then [ (e.g.
User Options TSD402 User Manual Change Passcode 1 (key 4 ) This option allows `User 1' to change their own passcode, normally when the system is handed over to you from the alarm company, the `User 1' passcode will be set to 5678. Change Passcode 1 UNSET Enter first 3 digits of Passcode then [ (e.g., 5 6 7 [) USER OPTION Press 4 for Passcode 1 PASSCODE 1 ---Enter new pascode (e.g., 2 5 8 0 ) PASSCODE 1 2580 Press [ to accept.
TSD402 User Manual User Options Change Passcode 2 (key 6 ) This option allows `User 1' to change the second user passcode. Change Passcode 2 UNSET Enter first 3 digits of Passcode then [ (e.g., 5 6 7 [) USER OPTION Press 6 for Passcode 2 PASSCODE 2 ---Enter new pascode (e.g., 7 8 9 0 ) PASSCODE 2 7890 Press [ to accept. UNSET A two-sound indicates acceptance, a single low tone indicates that the passcode is not available. Repeat again trying a different four digit number.
User Options TSD402 User Manual Home Area Configuration (key 7 ) This option allows `User 1' to select which zones will be omitted when the part-set (HOME) is selected. Only zones that are programmed by the alarm company as `Night' or `Access' may be omitted. Home Area UNSET Enter first 3 digits of Passcode then [ (e.g., 5 6 7 [) USER OPTION Press 7 for Home Area U7- O A A A A A Zone - 1 2 3 4 5 F/Exit The display shows which zones are Omitted (O) and Armed (A) for the Home Area Configuration.
TSD402 User Manual User Options Speech Dialler Programming (key 8 ) This option allows `User 1' to program the speech dialler options. When this option is selected the system will stay in the `Speech Dialler' programming menu until the `User 1' passcode is entered. The figure below shows the basic menu structure. Speech Dialler Menu UNSET Enter first 3 digits of Passcode then [ (e.g.
User Options TSD402 User Manual Programming Telephone Numbers The TSD402 can store up to three telephone numbers with a maximum of 16 digits for each. Before storing any telephone numbers, the permission of the persons being called must be obtained. The `Emergency Services' telephone number (999 &112) cannot be stored. When the TSD402 dials a telephone number it will automatically select the correct dialling format. Currently in the U.K.
TSD402 User Manual User Options Programming Telephone Numbers (Cont.) Normal Selecting Pulse or Tone Inserting a Pause for PABX systems READY READY READY Press [ Press [ Press [ ENTER 1-3 or 7-0 ENTER 1-3 or 7-0 ENTER 1-3 or 7-0 Press 1 for Tel No 1. Press 1 for Tel No 1. Press 1 for Tel No 1. PHONE No. 1 PHONE No. 1 Blank / current number Blank / current number Enter pre-fix number (e.g.
User Options Recording Messages The TSD402 has a built-in microphone speaker so that phrases can be recorded replayed directly from the unit. Messages formed by combining a common phrase (0) one of the alarm phrases (F, P or A). TSD402 User Manual and and are and When the out-going call is answered the unit plays the common phrase (0) and one of the three alarm phrases F, P or A. Phrase 0 normally states the name and address of the user and phrases F, P and A relate to the alarm type (FIRE ,PA, ALARM).
TSD402 User Manual User Options Replaying Messages Once the phrases have been recorded it is possible to play them back through the built-in loudspeaker within the TSD402. Replaying Messages READY Press 7 for Fire message Press 8 for PA message P ress 9 for Alarm message (e.g., press 9 ) After a short delay PLAYING PHRASE 0 PLAYING PHRASE A READY Call Acknowledgement procedure When the call is answered, the message is played.
User Options TSD402 User Manual Sending a Test Call It is possible to test that each message plays to each of the telephone numbers. e.g., you may want to test that ` Alarm Message' plays to telephone number 1 or the `Fire Message' to telephone number 3 etc. Before sending a test call it is very important that the person that is being called is familiar with the Call Acknowledgement Procedure. This will ensure that the TSD402 is successfully cleared down.
TSD402 User Manual User Options Test Activation The option allows the unit to simulate an alarm activation from one of the alarm channels (Fire, PA or Alarm). When this test option is used the unit will go through the sequence of dialling all telephone numbers until the call is acknowledged. The numbers it dials are dependent on how the `Dialler Reporting Options' are configured (see page 25) and how the `Acknowledgement Option' is set (see page 22). The example below shows the default operation.
User Options TSD402 User Manual Changing the Acknowledgement Option The TSD402 acknowledgement can be set to one of the following options: CLEARED BY ANY 1 - The TSD402 will clear-down when the call is acknowledged by any one of the three recipients (this is the default setting). CLEARED BY ANY 2 - The TSD402 will clear-down when the call is acknowledged by any two of the three recipients. CLEARED BY ALL 3 - The TSD402 will clear-down when the call is acknowledged by all three recipients.
TSD402 User Manual User Options Viewing the Last Call Log When a call is successfully acknowledged the TSD402 stores the event in a `Last Call Log'. When the log is viewed the display will show the alarm that was sent (F, P and A) and the telephone number(s) that acknowledged the call.
User Options TSD402 User Manual View Event Log (key 9 ) The TSD402 will store up to 64 events within the memory log. When this option is selected the most recent event is displayed first. Pressing the [ key takes you backwards through the Log and pressing the ] key abandons the View Log option. Table 1 shows event log descriptions. View Log UNSET Enter first 3 digits of Passcode then [ (e.g., 5 6 7 [) USER OPTION Press 9 for View Log Event Description UNSET 000 Event No.
TSD402 User Manual User Options Dialler Reporting Options (key 0 ) Each alarm type (Fire, PA or Alarm) may be programmed to report only to selected telephone numbers. For example the Fire activation may be programmed to report to all three telephone numbers, whereas the Alarm activation may be programmed to report only to telephone numbers 1 and 3 etc. Dialler Reporting Options UNSET Enter first 3 digits of Passcode then [ (e.g.
Remote Keypads TSD402 User Manual Remote Keypads Introduction The TSD402 system may have been fitted with one or more remote keypads to allow remote operation of the system. The remote keypad uses LED indicators to show zone faults and alarms, and an internal sounder to indicate exit and entry tones.
TSD402 User Manual Troubleshooting Troubleshooting Alarm System troubleshooting Problem - Cause - Action - Problem - Cause - Action - Problem - Cause - Action - Problem - Cause - Action - Problem Cause - Action - I enter my passcode to set the system but the panel gives me an intermittent sound and the display shows a zone is in fault. The tone indicates that a detector is active or a door has been left open. The display indicates which detector or door is active.
Troubleshooting TSD402 User Manual Problem - The display shows UNSET AC OFF and the internal sounders beeps every minute. The mains power to the panel is off or the internal fuse has blown. The system will operate from the internal battery for about 8 hours. Enter you passcode to silence the beeps, if the mains power to the building is on, contact your alarm company. Cause - Action - Problem Cause Action - When setting the system, the outside strobe starts to flash.
TSD402 User Manual Problem - Cause Action Cause Action - Problem - Cause - Action - Troubleshooting When the unit calls the recipient they can't acknowledge the unit by pressing the number [8] button. Incorrect acknowledgement procedure. Instruct the recipient in the correct procedure (see page 19). Incompatible telephone. Call the recipient and ask them to press the number [8] button on their telephone for 3 seconds.
Alarm System Details Zone Location HOME Area Chime 1 2 3 4 5 Final Exit Setting Mode: Final Exit Set Timed Exit Set Operation of Final Exit zone in Part-Set: Final Exit Instant System Reset By: Engineer Remote Reset Fire (Away) PA (Away) Alarm (Away) Fire (Home) PA (Home) Alarm (Home) User Entry Time: Seconds Exit Time: Seconds Bell Duration: Minutes Dialler Reports: Installation Company Address: Telephone No: For Remote Reset telephone: B.18985 Drg No.