User manual

Issue 02 Feb 92 Page 5 - 15
TS2000 (V2+) User Manual
STEP ACTION DISPLAY REMARKS
1 NO* Press <YES> to
USE TEST OPTIONS
Press YES to use Test Facilites menu. Press NO to go to Network
Options menu. Use arrow keys to step through menus. Press 0 to
quit
2 YES Press YES to
PUT CIRCUIT ON TEST
Press YES to select a circuit for test. Press NO to go to Start Timed
Test (step 9). Press 0 to return to step 1
3 YES CCT >001 (equipped)
Type/Text
Press YES to accept display and continue to next circuit or press NO
to change it. Use arrow keys to step through circuits. Use figures to
select new circuit
4 NO CCT 001 >(equipped)
Type/Text
Press YES to accept and leave circuit not on test (equipped) or NO
to change to 'on test' then press YES to accept
5 NO CCT 001 >(on test)
Type/Text
Circuit put on test - press YES to accept or NO to change back to
'equipped'
6 YES CCT >001 (on test)
Type/Text'
Press YES to accept display and continue to next circuit or press NO
to change it. Use arrow keys to step through circuits. Use figures to
select new circuit. Repeat steps 3 to 6 for other circuits if required.
Enter 000 to quit
7 000 CCT >000 not valid
YES to continue'
Selection complete. Press YES to return to step 2. Press 0 to go to
step 1
8 YES Press YES to
PUT CIRCUIT ON TEST
Press NO to go to Start Timed Test. Press YES to go to step 2.
Press 0 to go to step 1
9 NO Press YES to
START TIMED TEST
Press YES to select timed test or to view time left of an existing test.
Press NO to go to Cancel Timed Test. Press 0 to go to step 1
10 YES Enter No. of days
TEST TIME >00 days
Press YES to accept displayed days or use figures or arrows to enter
number of days of test then press YES to accept and start test
period. Enter 00 for an indefinite test period. Time ends at midnight
5.20 Use Test Options (Menu 21)
11 YES Press YES to
START TIMED TEST
Press NO to go to Cancel Timed Test. Press YES to repeat step 9.
Press 0 to go to step 1
12 NO Press YES to
CANCEL TIMED TEST
Press YES to cancel timed test. Press NO to go to Review Test
failures. Press 0 to go to step 1
13 YES TEST CANCELLED
Press any key to continue
Predss any key to continue
14 (YES) Press YES to
CANCEL TIMED TEST
Press NO to go to Review Test Failures. Press YES to go to step 13.
Press 0 to return to step 1
15 NO Press YES to
REVIEW TEST FAILURES
Press YES to see circuits that have been activated during test. Press
NO to go to Clear Test Failures. Press 0 to go to step 1
16 YES FAILED TEST CIRCUITS
Please check:-
List of failed circuits will be displayed
17 - Press YES to
REVIEW TEST FAILURES
Press NO to go to Clear Test failures. Press YES to repeat step 15.
Press 0 to go to step 1
18 NO Press YES to
CLEAR TEST FAILURES
Press YES to to clear log of test failure record. Press NO to go to
step 2. Press 0 to go to step 1
19 YES FAILURES RESET OK
Press any key
Press any key to continue
20 (YES) Press YES to
CLEAR TEST FAILURES
Press NO to go to See Version menu. Press 0 to go to step 1
(continued)