User manual

Issue 02 Feb 92 Page 5 - 14
TS2000 (V2+) User Manual
STEP ACTION DISPLAY REMARKS
1 NO* Press <YES> to
DEFINE PANEL MODES
Press YES to Define Panel Modes. Press NO to go to Test Facilities
menu. Use arrow keys to step through menus. Press 0 to quit
2 YES At end of exit, set
with 'Last Exit'
Press YES to accept or NO to change to 'Exit Terminator' or 'Exit
Timer' then YES to accept. Use arrow keys to step through Exit
modes. Press 0 to go to step 1
3 YES Remote Service
'anytime'
Press YES to accept or NO to change to 'needs User Code' then YES
to accept. Use arrow keys to step between them. Press 0 to go to step
1
4 YES Output modules will
'mimic circuits'
Press YES to accept or NO to change to 'show circuit alarms' then
YES to accept. Use arrow keys to step between them. Press 0 to go to
step 1
5 YES PA's in walk test
'are tests'
Press YES to accept or NO to change to 'Will cause alarms' then YES
to accept. Use arrow keys to step between them. Press 0 to go to step
1
6 YES User setting system
'barred with Line-Ft'
Press YES to accept or NO to change to 'O.K. with Line-Ft' then YES
to accept. Use arrow keys to step between them. Press 0 to go to step
1
7 YES User setting system
'barred with A.C. off'
Press YES to accept or NO to change to 'O.K. with A.C. off' then YES
to accept. Use arrow keys to step between them. Press 0 to go to step
1
8 YES Time lock facility
'applies to system'
Press YES to accept or NO to change to 'applies to Ward 01' then
YES to accept. Use arrow keys to step between them. Press 0 to go to
step 1
9 YES For alarm in system
'digi-com is instant'
Press YES to accept or NO to change to 'digi-com is delayed' then
YES to accept. Use arrow keys to step between them. Press 0 to go to
step 1
10 YES Panel Alarm Mode
'Re-arm is Automatic'
Press YES to accept or NO to change to 'Re-arm is Manual' then YES
to accept. Use arrow keys to step between them. Press 0 to go to step
1
11 YES Panel Alarm Mode
'Reset by User'
Press YES to accept or NO to change to 'Reset by Engineer' then YES
to accept. Use arrow keys to step between them. Press 0 to go to step
1
12 YES Engineer and User
'Codes are 4 digits'
Press YES to accept or NO to change to 'Codes are 6 digits' then YES
to accept. Use arrow keys to step between them. Press 0 to quit
13 0 Press <YES> to
DEFINE PANEL MODES
Press NO to go to Use Test Options menu. Press YES to repeat this
menu. Use arrow keys to step through menus. Press 0 to goto step 1
* from last step of previous menu
5.19 Define Panel Modes (Menu 20)