User manual
Issue 02 Feb 92 Page 5 - 12
TS2000 (V2+) User Manual
STEP ACTION DISPLAY REMARKS
1 NO** Press <YES> to
DEFINE OUTPUTS
Press YES to Define Outputs. Press NO to go to Review Wards
menu. Use arrow keys to step through menus. Press 0 to quit
2 YES Press <YES> to
ALTER PANEL OUTPUTS
Press YES to alter PANEL outputs. Press NO to alter NODE outputs
then YES to continue
3 YES O/P >001 (Panel)* is
(Output Type)
Press YES to accept displayed Panel or Node output configuration
and go to next output. Press NO to change it. Use arrow keys to step
through output number. Enter figures to select new output number
4 YES O/P >002 (Panel)* is
(Output Type)
O/P 001 displayed configuration accepted. Press YES to accept
displayed output number. Press NO to change it. Use figures or
arrows to change output number
5 NO O/P 002 (Panel)* is
> (Output Type)
Output to be changed. Press NO to change and YES to accept. Use
arrow keys to step through output types
6 YES O/P >002 (Panel)* is
(new Output Type)
New configuration accepted. Continue steps 3 to 6 until all outputs
are defined then enter 000 to continue
7 000 O/P >000 invalid No
YES to continue
Press YES or NO to return to step 1
8 YES Press YES to
DEFINE OUTPUTS
Press NO to go to Review Wards menu. Press YES to repeat this
menu. Use arrow keys ro step through menus. Press 0 to quit
** from last step of previous menu
* or Node
5.15 Define Outputs (Menu 16)
STEP ACTION DISPLAY REMARKS
1 NO* Press <YES> to
REVIEW WARDS
Press YES to Review Wards. Press NO to go to Define Ward Alarms
menu. Use arrow keys tostep through menus. Press 0 to quit
2 YES CCT >001 in Ward(s)
* * * * * * * *
Press YES to accept displayed information and go to next circuit.
Press NO to return to step 1. Use arrow keys to step through cicuits.
Enter figures to select Circuits. Press 000 then YES to reurn to step 1
3 YES CCT >002 in Ward(s)
* 2 * * * * * *
Information accepted. Circuit 2 is in ward 2. Continue as in step 2
4 000 CCT >000 NOT VALID
YES to continue
Press YES/NO to go to step 1
5 YES Press YES to
REVIEW WARDS
Press NO to go to Define Ward Alarms menu. Press YES to repeat
this menu. Use arrow keys to step through menus. Press 0 to quit
* from last step of previous menu
5.16 Review Wards (Menu 17)