User manual
Issue 02 Feb 92 Page 5 - 4
TS2000 (V2+) User Manual
STEP ACTION DISPLAY REMARKS
1 No* Press <YES> to
USE CHIME FACILITY
Press YES to use Chime Facility. Press NO to go to use the Printer.
Use arrow keys to step through menus. Press 0 to quit
2 YES Press YES to
ALTER CHIME CIRCUITS
Press YES to alter circuits that chime. Press NO to go to Enable
System Chime. Press 0 to go to step 1. Use arrow keys to step
through menus
3 YES CCT >123 Silent
Type or Text
First night circuit which at present is silent. Press YES to go to next
circuit. Press NO to change this circuit. Use arrows to step through
circuits. Enter figures to select circuit
4 NO CCT 123 >Silent
Type or Text
Circuit retained and condition to be changed. Press NO to change
and YES to accept chime or silent
5 NO CCT 123 >Chimed
Type or Text
Condition changed. Press YES to accept change . Press NO to
change again then YES to accept.
6 YES CCT >123 Chimed
Type or Text
New condition accepted. Continue steps 3 to 6 for other circuits or
enter 000 to quit
7 000 CCT >000 NOT VALID
YES to continue
Press YES to return to step 1
8 YES Press YES to
USE CHIME FACILITY
Press YES to Use Chime Facility. Press NO to use the Printer. Use
arrow keys to step through menus. Press 0 to quit
9 YES Press YES to
ALTER CHIME CIRCUITS
Press NO to to go to Enable System Chime.Press YES to alter
circuits that chime. Press 0 to go to step 1. Use arrows to step
through menus.
5.7 Chime Facility (Menu 8)
10A No OR Press <YES> to
ENABLE SYSTEM CHIME
Press YES to activate System Chime Facility. Press NO to go to
Ward Chime (if applicable) or to step 1 if no wards defined. Use
arrow keys to step through menus. Press 0 to quit
10B NO Press YES to
CANCEL SYSTEM CHIME
Press YES to disable System Chime Facility. Press NO to go to
Ward Chime (if applicable) or to step 1 if no wards defined. Use
arrow keys to step through menus. Press 0 to quit
11A YES OR CHIME ENABLED OK
Press any key
System night circuits set to chime will chime if activated. Press any
key to go to step 1 or to step 12
11B YES CHIME CLEARED OK
Press any key
System night circuits set to chime will not chime if activated. Press
any key to go to step 1 or to step 12
12 YES Press YES to
ENABLE CHIME WARDS
Only if Wards are defined. Press YES to enable wards to chime.
Press NO to go to step 1
13 YES CHIME ON WARD(S)? :-
* * * * * * * *
Night circuits set to chime in wards Wards indicated will chime if
activated. Enter figures to change wards. Enter 0 to clear all wards
14 (fig) CHIME ON :- * * (fig) * *
Press any key
Wards indicated will chime. Press any key
15 (YES) Press YES to
USE CHIME FACILITY
Press NO to use the Printer. Press YES to Use Chime Facility.Use
arrow keys to step through menus. Press 0 to quit
* from last step of previous menu