User manual
Issue 02 Feb 92 Page 4-3
TS2000 (V2+) User Manual
4.4 Set System and Some or No Wards (without WCU). Circuits may be Omitted
STEP ACTION DISPLAY REMARKS
1 - SYSTEM UNSET
(date) (time)
System and all Wards are unset
2 Enter passcode Press YES to
START SET SEQUENCE
Press YES to continue. Press 0 to quit. (Press NO to go to other
Menus)
3 YES SET?:- System (9) &
Ward 1 (to) 8**
Only Wards with circuits will be displayed. Enter numbers of wards not
to be set - figures will 'toggle'. Press NO to Omit circuits and return -
see Para 5.6. Press 0 to return to step 2. (Press YES to set)
4 1 > 8 SET?:- System (9) &
Ward 1 (to) 8**
Only Wards remaining and with circuits will be displayed. Press YES to
set these Wards and the system. Press NO to Omit circuits and return -
see Para 5.6. Press 0 to return to step 2
5 YES (OR) Ward set 1 (to) 8** Wards (without WCU) being set, if any, momentarily displayed
6A YES *YOUR EXIT IS TIMED
xx mins yy secs left (OR)
Timed exit. Leave via the exit route within the time shown
6B - *LEAVE VIA EXIT ROUTE
All circuits healthy
Leave via the Last Exit and use the Exit Terminator if required
7 Last exit closed *EXIT MODE COMPLETE
Attempting to set
Exit time complete, or Last Exit used, or Last Exit used and Exit
Terminator operated.. Delay for Exit Settling time
8 - SET SYSTEM . . . . . . . .
(date) (time)
System and applicable wards (if any) all set ONLY when the sounder
stops
* = Sounder on
** = Only Wards with circuits are displayed
Steps 5 to 7 are the Exit Sequence
4.5 Set Wards but not the System. Circuits may be Omitted
STEP ACTION DISPLAY REMARKS
1 - SYSTEM UNSET
(date) (time)
System and all Wards are unset
2 Enter passcode Press YES to
START SET SEQUENCE
Press YES to continue. Press 0 to quit. (Press NO to go to other
Menus)
3 YES SET?:- System (9) &
Ward 1 to 8**
Only Wards with circuits will be displayed. Enter 9 to delete system and
numbers 1 to 8 of wards not to be set - figures will 'toggle'. Press NO to
Omit circuits & return - see Para 5.6. Press 0 to return to step 2
4 9 & 1 (to) 8 SET?:- only
Ward 1 (to) 8
System deleted. Only Wards not deleted will be displayed. Press YES
to set these Wards and go to step 5A 0r 5B. Press NO to Omit circuits
and return - see Para 5.6. Press 0 to return to step 2
5A YES Ward set 1 (to) 8 Wards without WCU being set momentarily displayed. Go to step 5B or
6
5B YES SYSTEM UNSET
(date) (time)
Wards with WCU being set using Exit procedure. WCU Sounder on.
6 0 SET 1 (to) 8
(date) (time)
WCU sounder off. Only the wards indicated are set
** = Only Wards with circuits are displayed
If Passcode Standard (W) is used omit steps 3, & 4