FULLVIEW RECTANGLE DIRECT VENT GAS FIREPLACE HEATER Model FV41 INSTALLATION INSTRUCTIONS MANUAL DOCUMENT NO. FV41-IM-0610 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Open windows. Do not touch electrical switches. Do not try to light any appliance. Extinguish any open flame. Do not use the phone in your building.
SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instructions may result in a possible fire hazard and will void the warranty. Any safety screen or guard removed for servicing must be replaced before operating this appliance. DO NOT USE this appliance if any part has been under water.
TABLE OF CONTENTS SAFETY AND WARNING INFORMATION SPECIFIC REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS FV-41 FULL VIEW GAS FIREPLACE DIMENSIONS TECHNICAL SPECIFICATIONS FOR FV-41 MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS CONGRATULATIONS BUILDING PERMIT AND INSTALLATION INSPECTION APPROVAL REQUIREMENTS GENERAL APPLIANCE SPECIFICATIONS MANTEL CLEARANCES CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES PLANNING THE INSTALLATION SELECTING APPLIANCE LOC
FLAME APPEARANCE ADJUSTMENT FLAME APPEARANCE ADJUSTMENT- AIR SHUTTER ADJUSTMENTS FLAME APPEARANCE ADJUSTMENT- EXHAUST DAMPER ADJUSTMENTS TROUBLE SHOOTING THE FV-41 FIREPLACE & MAINTENANCE INFORMATION OVER FIRING OF BURNER MAINTAINING CORRECT PILOT-FLAME, PILOT OUTAGE & RELIGHTING CLEANING VIEWING GLASS SOOTING OPERATION DURING POWER FAILURE GAS SHUTOFF PROCEDURE MAINTENANCE NATURAL TO LP GAS CONVERSION Read Before Attempting NG to LPG Conversion ORIFICE SIZES REQUIREMENT: LP PRESSURE REGULATOR CONVERSION
Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common Wealth of Massachusetts only. a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes and where the side wall exhaust vent termination is less than seven (7) feet above grade, the following requirements shall be satisfied: 1.
FV-41 FULL VIEW GAS FIREPLACE DIMENSIONS OVERALL APPLIANCE DIMENSIONS AND FEATURES 20 9/16 in 19 5/8 in 19 3/16 in 9 1/16 in 10 1/8 in 19 3/16 in 40 3/8 in 19 3/16 in 39 1/4 in 8 1/16 in 8 1/16 in 19 5/8 in 6 3/8 in 35 in 43 1/16 in 36 3/16 in 4 7/8 in 13 13/16 in 23 15/16 in 43 1/16 in 32 1/2 in 4 7/8 in ACCENT LIGHT HOUSING 5"X8" COAXIAL VENT STARTER COLLAR HEAT TRANSFER DUCTS CONNECTION PORTS 5"x8" COAXIAL STARTER COLLAR LH LIFT HANDLE LIFT HANDLE VISIBLE GLASS AREA 26-1/4" X 29-
TECHNICAL SPECIFICATIONS FOR FV-41 MODEL FV41 BTUH. (MODEL FV-41) BTUH. (MODEL FV-41) High Fire - Adjustable to - Low Fire NAT. GAS LP GAS 40,000 40,000 13,000 15,000 NOTE: LPG CONVERSION KIT, #New #, MUST BE PURCHASED SEPARATELY TO CONVERT TO BURN LPG IN THIS FIREPLACE. MAIN ORIFICE [0-2000ft (610 m)]: REAR BURNER: #42 NG [#54 L.P.] ± FRONT BURNER: #42 NG [#54 LP] ........................ [2000-4500ft (610-1370 m)]: REAR BURNER: #43 NG [#55 L.P.] ± FRONT BURNER: #43 NG [#55 LP] OVERALL EFFICIENCY: .
CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of beauty and interest in your home. The Mendota Gas Fireplace is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace.
FV41 DIRECT VENT GAS FIREPLACE GENERAL APPLIANCE SPECIFICATIONS HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. 1" MIN. 422 ROUGH FRAMING WIDTH 35-1/2" 493 4" 9" TO VENT PIPE CENTER 1" 328 11" 1716 19-1/2" MIN.
MANTEL CLEARANCES Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. For ease, however, measure up from the floor level of this fireplace.
CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES Figure 2: Clearances to Combustibles 0" CLEARANCE FROM TOP STANDOFFS 1/2" CLEARANCE FROM BACK 1/2" CLEARANCE FROM SIDES 11 | P a g e
PLANNING THE INSTALLATION When planning on appliance installation, it is necessary to determine the following information before installing: Where the appliance is to be installed. The vent system configuration to be used. Gas supply piping. Electrical Wiring. Framing and finishing details. Hearth Protection Pad Requirements. Whether accessories such as a wall switch, remote control, and ceiling fan are desired.
ROUGH FRAMING DIMENSIONS Rough Framing Dimensions The Rough Framing Dimensions must be maintained to allow this fireplace to slide into the fram0 ing cavity with a 90 elbow installed on the top starter collar. After the FV-41 Fireplace is inserted into the rough framed cavity, install one 2x4 on HDFK VLGH DGMDFHQW WR WKH VLGH RI WKLV ILUHSODFH¶V body and one 2x4 on top of the top framing standoffs to close the air gap and to act as nailing studs for finishing materials.
FRAMING DEPTH and FINISHING GUIDES The framing depth for this fireplace is 19-1/2 inches. This is a fixed depth required for all installations, except a corner installation and for installations that use solid Granite or Marble slabs as fascia materials. For corner installations, see figures 1 and 4.
FINISHING MATERIALS INSTALLATION All finishing PDWHULDOV WKDW VXUURXQG WKLV ILUHSODFH¶V rectangle profile must extend out from the face surface of this fireplace 1 inch. Tiles and Faux Rock If installing Tiles or )DX[ 5RFN ILUVW LQVWDOO D ò´ WKLFN (minimum) Cement Board (Hardibacker or Durock Brand) over the face of the fireplace and framing members. Follow by applying Thinset mortar (no polymer additives) XVLQJ ó´ VTXDUH notched trowel on the cement board surface.
HEARTH PROTECTION PAD REQUIREMENTS Hearth Protection R Rating: MINIMUM R- ,6 5(48,5(' 86( 2) $ ò´ 7+,&. 0,1,080 &(0(17 BOARD (HardiEDFNHU :RQGHUERDUG RU RWKHU EUDQG SOXV ó´ WKLFN PRUWDU 7KLQ6HW W\SH SOXV ó´ WKLFN FHUDPLF WLOH H[FHHG WKH 5-1 reTXLUHPHQW 8VH WKLV DV D UHIHUHQFH LI LQ GRXEW 1DWXUDO 6WRQHV RI ´ RU JUHDWHU WKLFNQHVV DOVR H[FHHG 5-1 rating. All hearth pads must be non-combustible (metal, brick, stone, or mineral fiberboard).
GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced and highly efficient system brings in outside air for combustion, has a separate exhaust vent and efficiently heats and re-circulates room air. The Mendota system maintains high air quality, maximizes efficiency and assures proper operation in today's "air-tight" homes.
GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fireplace. Be sure the gas supplier or plumber carefully checks for correct gas pressure and gas line sizing when installing the fireplace. GAS LINE INLET 1/2" FNPT REQ'D It is critical to carefully check for gas leaks when hooking up the fireplace -- check with soap & water solution.
GAS PRESSURE REQUIREMENTS One of the main causes of operating problems with gas appliances can be improper gas pressure! Problems such as changes in flame color or configuration, gas pilot or burner outages, intermittent operation, changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure or improper gas pressure at the time of the installation.
GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements. The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the absence of local codes, the installation must conform to the most current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54.
GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using the Mendota approved vent system components. Approved brands of vent components include DuraVent, Amerivent, Selkirk and Security vent pipes and venting components.
EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 12: Exterior Vent ALL MEASUREMENTS FROM CENTER-LINE OF VENT CAP - Vent Terminal A= B= - Air Supply Inlet Clearance above grade, veranda, porch, deck, or balcony (*12 inches (30 cm) minimum). Vinyl surfaces reTXLUH ´ PLQ Clearance to window or door that may be opened (*12 inches (30 cm) minimum.
FLUE VENTING COMPONENTS IDENTIFICATION DO NOT SEPARATE TELESCOPING SECTIONS. USE TELESCOPING SECTIONS AS COMPLETE ASSEMBLIES. HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
FV-41 MASTER FLUE VENTING REQUIREMENTS CHART NOTE: THIS CHART IS APPLICABLE TO BOTH NATURAL GAS AND LPG INSTALLATIONS. IMPORTANT NOTES: See Figure 15, below. 0 1. 18 inches maximum horizontal pipe run allowed with a 90 HOERZ FRQQHFWHG GLUHFWO\ WR WKLV ILUHSODFH¶V IOXH VWDUWHU FRllar. 2. Maximum Vertical Run allowed is 61 feet. 3. Maximum Vent System length allowed is 65 feet. 24 | P a g e ZONE "A" IN ZONE "A", ADJUSTABLE EXHAUST DAMPER MUST BE FULLY OPEN.
IMPORTANT VENTING CONFIGURATION NOTES See Figure 14 [MASTER FLUE VENTING REQUIREMENTS CHART]. HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions. MAXIMUM HORIZONTAL RUN A.
APPROVED VENT SYSTEMS QUICK REFERENCE CHART Figure 15: Vent Systems STRAIGHT UP, VERTICAL VENTING ZERO VERTICAL HORIZONTAL TERMINATION H H VERTICAL RISE HORIZONTAL TERMINATION 61 FEET MAXIMUM V APPROVED APPROVED APPROVED VERTICAL RISE DUAL 90° ELBOWS HORIZONTAL TERMINATION H H1 V2 H2 V H V1 ZERO VERTICAL DUAL 90° ELBOWS VERTICAL TERMINATION APPROVED VERTICAL RISE DUAL 90° ELBOWS VERTICAL TERMINATION V APPROVED APPROVED H2 VERTICAL RISE TRIPLE 90° ELBOWS VERTICAL TERMINATION V2 THREE
ZERO RISE HORIZONTAL TERMINATION The FV-41 Fireplace must be installed by a qualified Mendota approved serviceperson. A Maximum Horizontal Run allowed is 18 inches if a 90-GHJUHH HOERZ LV FRQQHFWHG GLUHFWO\ WR WKLV ILUHSODFH¶V IOXH VWDUWHU collar.
VERTICAL RISE HORIZONTAL TERMINATION The minimum vertical section required to be connected directly to the starter adapter on this fireplace is 48 inches when used with a maximum horizontal run of 20 ft. If the total length of the vertical sections connected directly to the starter adapter on this fireplace is between 4 feet and 41 feet, you are allowed a maximum 20 feet horizontal run.
Figure 19 APPROVED Figure 20 29 | P a g e
VERTICAL THROUGH-THE ROOF VENTING The maximum vertical run of vent pipe is 51 ft. from the top of the fireplace. The fireplace will support a run of a maximum of 61 ft. Maintain 1" air space clearances on all sides of vents (2" above horizontal runs). o If an offset is required directly on top of the fireplace, two 45 elbows may be connected directly to the top of this fireplace to create a horizontal offset then to run upwards vertically.
. Figure 21 12 11 9,10 15 13 61 FEET MAX.
VERTICAL THROUGH-THE-ROOF VENTING USING FOUR 900 ELBOWS 0 In extreme situations, Four 90 elbows may be required to reach a proper exit point for the vent system. Mendota has spent considerable time and effort in the design of this fireplace and its venting system. Through this effort, Mendota has 0 been able to certify the use of Four 90 elbows. 0 The use of Four 90 elbows must meet some minimum prerequisites. Prerequisite #1: The vent system must terminate vertically using a vertical vent cap.
FV-41 DOOR OPERATION TO REMOVE DOOR 1. Use the glass latch tool to disconnect the spring latches from the glass frame. Insert tool into hole in latch, pull towards you and Rotate 90 degrees to disengage top latches. Remove tool. There are two spring latches on top of this gas fireplace. 2. With both hands, rotate top edge of glass frame away from unit 12 inches. 3. Lift glass frame up 1 inch, at an angle, and move away from unit. 4. Door is now free from unit. TO REPLACE DOOR 1. 2. 3. 4. 5.
INSTALLATION CHECK OFF LIST Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved person in accordance with instructions. All joints must be secured, "twistlocked" and leak-proof. 1000ºF sealant must be used on the inner pipe joints of all DuraVent pipe sections. Horizontal or vertical vent cap must be installed "right-side-up" and tightly sealed to structure per instructions. Vent Caps must be Mendota approved.
BLOWER SYSTEM INFORMATION WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from the plug. Dual blowers are provided as standard equipment with this FV-41 fireplace.
FLAME APPEARANCE ADJUSTMENT AIR SHUTTER ADJUSTMENTS Be sure burner and logs are properly installed (see FV-41 Log Set Installation Section). After burner has been properly installed and operated for 20 minutes, small additional adjustments to the air shutter may be necessary for final flame appearance.
TROUBLE SHOOTING THE FV-41 FIREPLACE & MAINTENANCE INFORMATION SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating (soot) forms on viewing glass. A. Incorrect gas pressure 2. Humming or whistling coming from Fireplace. A. Normal operating noise. Some noise is normal. It is caused by the gas supply flowing through the gas orifice. It is expected from any gas fireplace. Turning the Hi/Lo Knob on the control can reduce the noise.
MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved service person. NOTE: Any adjustments to burner, pilot or logs must be done by a qualified Mendota service person. A. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or damage. B. Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs.
NATURAL TO LP GAS CONVERSION Kit # HA-78-00179 for Mendota Model FV-41 This conversion kit shall be installed by a qualified service agency in accorGDQFH ZLWK WKH PDQXIDFWXUHU¶V LQVWUXFWLRQV DQG DOO DSSOLFDEOH codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
WARNING: It is of the utmost importance that the correct burner orifices be installed for both the rear and front burners. It is highly recommended that you remove the left side blower assembly and the left side exterior controls box before attempting to replace the pressure regulator. 1. Turn off gas supply at the appliance service valve. 2. See diagrams on this page and identify the Pressure Regulator on the VIEW FROM OUTSIDE FIREBOX Valve Body. 3.
LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the outer left side of the fireplace. A qualified installer shall take pressure measurements at these ports to verify and set the correct gas pressures during the LP Kit installation and before facia materials are installed over the front of this fireplace.
CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS Once the conversion to LPG and all the above steps have been completed, light the main burners. Turn Gas Dial counterclockwise to "ON" then set Thermostat or push Main Burner ON/OFF switch to turn on burners. Main burner should now light IMMEDIATELY and flame should not "lift" off burner.
FV-41 VALVE ASSEMBLY REPLACEMENT PARTS ITEM 1 2 3 4 5 6 7 8 9 10 11 12 QTY 1 2 1 2 1 1 1 1 2 1 1 1 FV-41 VALVE ASSEMBLY REPLACEMENT PARTS LIST PART NUMBER DESCRIPTION HA-77-00159 VALVE HEAT SHIELD 65-07-00024 1/8 NPT to Flex CF Coupler 05-04-00050 SIT Pilot Assembly 65-14-00042 ORIFICE, #42 22,197 BTU NAT 05-02-00344 885 PROFLAME SIT VALVE 05-02-00351 Solenoid, 885 PROFLAME SPLIT FLOW VALVE 60-01-00018 NIPPLE, 3/8" NPT X 1.5" LONG, 0.
FV-41 GAS IGNITION SYSTEM WIRING DIAGRAM 45 | P a g e
GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT DO NOT substitute other manufacturer's materials or components. DO NOT operate unit with cracked, broken or missing glass. DO NOT abuse the glass door by striking the glass, slamming the door shut, etc WARNING Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or damaged glass. WARNING Do not operate this appliance with the glass removed, cracked or broken.
LISTING LABEL INFORMATION The model information regarding your specific appliance can be found on the rating plate, which is located inside the right side controls access door. When contacting your dealer for any cleaning service or warranty service, always provide the Model Number, Serial Number and Manufactured Date. This information will expedite the warranty verification process.
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Registration to Mendota.
NOTES 49 | P a g e
TAPE SHUT ------------------------------------------------------------------------------------------------------------------------------------------------------------- POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W.
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA FV-41 DIRECT VENT FIREPLACE Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and Limited Warranty to the original purchaser of a Mendota FV-41 Fireplace, which is limited and used under normal home conditions. STANDARD WARRANTY: JOHNSON GAS APPLIANCE CO.
Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com or www.mendotahearth.