Owner`s manual

REMOTE CONTROL UPGRAGE KIT -DXV35 DT3
INSTALLATION INSTRUCTIONS
Page 20 of
32
BEFORE YOU BEGIN
Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2).
Failure to follow the instructions may result in property damage, bodily injury, or even death.
Remote Control Transmitter Functions
NOTE: The Wall Receiver will “beep” once every time
a Remote Transmitter Key is pressed, signaling that
the command has been received.
Identify the four function buttons on the Remote
Transmitter:
1. ON/OFF KEY: This button
turns the system ON or OFF.
When this button is pressed
and the system is OFF, the
pilot light will stay ON if the “Standing Pilot
Switch” is in the ON position.
2. THERMOSTAT KEY: This button, when pressed after the ON/OFF KEY is pressed and the
system is ON, will allow the selection of three modes: Manual Operation, Normal Thermostat
and Smart Thermostat.
a. Manual Mode: In this mode, the room temperature is ignored and the fireplace can be turned ON indefinitely.
The room temperature rise has no effect on this mode. All other functions such as flame height control,
secondary burner On/OFF control and Accent Light ON/OFF controls will be manually controllable. Fan speed
will be manually controllable always but if unit is
hot, fan cannot be turned to OFF.
b. Normal Thermostat: In this mode, the fireplace
will stay functioning until the room temperature
increases 1
o
F above the Set Point Temperature.
To increase the Set Point Temperature, Press the
UP button until the desired temperature is
displayed in the SET POINT TEMPERATURE
window. The fan will turn on 5 minutes after
fireplace startup or when fireplace warms up and
will turn off 12-1/2 minutes after the flames turn off
or when unit cools down, in this mode. The flame
height can be adjusted while the fireplace is
functioning, fan speed can be adjusted after 5
minutes of startup. Secondary burner can be
turned On or Off at any time after startup. The
Accent Light can be turned on or off any time after
startup.
c. Smart Thermostat: In this mode, all other functions except the flame height adjustment are allowed. Manual
flame height adjustment is not allowed in this mode. The Smart Thermostat function adjusts the flame height
in accordance to the difference between the set point temperature and the actual room temperature. As the
room temperature gets closer to the set point temperature, the Smart Function automatically modulates the
flame down.
UP/DOWN KEY: This key is used to increase or decrease the Set Point Temperatures, Flame Height
and Fan Speed and to toggle between Accent Light ON/OFF and Secondary Burner ON/OFF.
MODE SELECTION KEY: This key is used to toggle between the various function icons:
Flame Height, Fan Speed, Accent Light and Secondary Burner.
SMART
ON
OFF
SMART
MODE
NORMAL
THERMOSTAT
MANUAL
MODE
68Hi
MAXMAX
Hi
OFF
76°
FF
76°
ON SMART
76°
F