Owner`s manual

REMOTE CONTROL UPGRAGE KIT -DXV35 DT3
INSTALLATION INSTRUCTIONS
Page 14 of
32
STEP 6: INSTALLING THE “WIRE HARNESS – RECEIVER CONNECTION” (item #7)
A total of 6 different connections must be made for the entire system to operate properly.
i. Connection to the Remote Control Receiver (RECEIVER)
ii. Connection to the Fan Control Module (FCM-COM)
iii. Connection to the Motorized Pressure Regulator (MOTOR)
iv. Connection to the Rear Burner Solenoid Valve (SPLITFLOW)
v. Connection to the DC-Supply connector (DFC-SUPPLY)
vi. Connection to the Green colored TH terminal and the White Colored TPTH terminal (TPTH and TH)
Follow the instructions in the order given. Although there are SIX connections to be made, all six connections are unique
in shape and color and cannot be mistaken. Below, is a general wiring diagram that will help you identify the first four
connections. Connections 5 & 6 are now shown here. Detailed diagrams are provided in the specific sections in this
manual that cover the #5 & #6 connections.