STEP 3: FAN SYSTEM SECONDARY WIRING INSTALLATION
Look into the unit cavity behind the gas valve. Locate a loose cable bundle with a label that reads “FCM FAN PLUG
ONLY”. This cable bundle has three wires: White, Black and Green.
Remove the Male connectors that are plugged on the ends of all three wires and discard the loose Male connectors.
Locate item #8 of the shipment you received “PLUG WIRE HARNESS – blower system”.
Connect the color matched ends of the PLUG WIRE HARNES to the ends of the “FCM FAN PLUG ONLY” labeled wire
bundle.
WARNING: CONNECT WHITE TO WHITE, BLACK TO BLACK AND GREEN TO GREEN ONLY! IF YOU DO NOT
MATCH WIRE COLORS IN THIS STEP, YOU WILL CREATE A SHORT CIRCUIT THAT WILL DAMAGE THE FANS,
THE FAN RHEOSTAT, THE FCM AND OTHER COMPONENTS.
Once the connections are made, insert the PLUG WIRE HARNESS into the receptacle in the Fan Control Module (FCM)
labeled ‘FAN”.
IMPORTANTNOTE
RHEOSTAT MOUNTED IN COURTESY PANEL TO CONTROL BLOWER SPEED MUST BE ADJUSTED TO THE
LOWEST BLOWER SPEED LEVELWHEN THIS REMOTE CONTROL KIT IS INSTALLED. IF YOU DO NOT ADJUST
THE RHEOSTAT SPEED TO ITS LOWEST SETTING AND THE RHEOSTAT IS SET AT A HIGHER SPEED, THE
REMOTE CONTROL WILL ONLY REGULATE THE BLOWER SPEED DOWN TO THE SPEED LEVEL THAT THE
RHEOSTAT IS SET AT. TURN THE RHEOSTAT KNOB TO ITS LOWEST SPEED POSITION!
BLUE
T-TAPS
GROUND
B
L
A
CK
GREEN
B
LA
C
K
W
H
I
T
E
W
H
I
T
E
B
L
A
C
K
GREEN
F
C
M
F
A
N
P
L
U
G
O
N
L
Y
LH BLOWER
RH BLOWER
A
C
C
E
N
T
L
I
G
H
T
P
L
U
G
H
A
R
N
E
S
S
F
C
M
F
A
N
P
L
U
G
H
A
R
N
E
S
S
RIGHT SIDE
OUTLETS
FAN CONTROL
MODULE
TO ACCENT
LIGHT HOUSING
LIGHT
DIMMER
BLOWER
RHEOSTAT
SNAPDISK
H
W
H
W
H
W
H
W
H
W
H
W
H
W
RHEOSTAT KNOB MUST BE TURNED TO “LOW”.
ONCE THE REMOTE CONTROL KIT IS INSTALLED,
THIS KNOB HAS NO FUNCTION EXCEPT TO SET
THE LOWEST BLOWER SPEED. IF YOU DO NOT
SET IT TO LOW, THE REMOTE SYSTEM WILL NOT
BE ABLE TO MODULATE THE BLOWER SPEED
BELOW THE SPEED THAT IS SET WTH THIS
RHEOSTAT.