Operating instructions
27
CORNER INSTALLATION USING THE REAR VENT OPTION
NOTE: The horizontal run of vent pipe must be level or have a ¼" rise for every 1' of run toward the termina-
tion. Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire.
USING OFFSETS AND RETURNS: A single 45
º
horizontal elbow is already calculated into the allowable
maximum 9” horizontal run. NO OTHER ELBOWS OR OFFSETS ARE ALLOWED!
CAUTION: Be sure to maintain 1" air space to any combustibles (2" above horizontal runs). The DXV-35
Fireplace must be installed by a qualified service person.
Mendota recommends the use of Duravent 5”X 8” coaxial pipes and fittings. Duravent components pro-
vide the most flexibility since Duravent horizontal termination caps slide fully over the 6” or 9” straight
pipe section used.
64 5/32
ADJUSTABLE
45 Deg L
44 29/32
4 3/32 FOR 2X4 WALLS
2 19/32 FOR 2X6 WALLS
4 3/32 FOR 2X4 WALLS
2 19/32 FOR 2X6 WALLS
6" LENGTH MINIMUM
9" LENGTH MAXIMUM
45 DEG.
ELBOW
6" PIPE MINIMUM REQ'D
9" PIPE MAXIMUM ALLOWED
44 29/32
10 13/16
FOR 2x4 WALLS, USE THESE DIMENSIONS. FOR 2X6 WALLS, MOVE
FIREPLACE CLOSER TO WALLS IN EACH DIRECTION 2". USE A 9" PIPE
SECTION IF YOU DESIRE A WIDER DIAGONAL MEASUREMENT.