INSTRUCTIONS FOR VENTING OFF THE REAR
ORIFICE SIZES REQUIREMENT
: When the DXV35 employs the rear vent option, the rear
burner orifice must be changed in the Natural Gas configuration to a #53 Spud Orifice (supplied
with the Fireplace) and in an LPG configuration to a #61 Spud Orifice (supplied with the Fire-
place). The front burner orifice remains unchanged at #42 for Natural Gas applications and #55
for LPG applications.
This section covers all pertinent information regarding the installation of this DXV-35
Fireplace using the Rear Vent option. Read this entire section thoroughly before at-
tempting to install this DXV35 Fireplace using the Rear Vent option. Failure to follow all
directions and failure to observe all restrictions and clearances can result in property
damage, bodily injury or can lead to death.
VENTING OFF THE REAR REQUIRES DURAVENT 5” X 8” COAXIAL RIGID PIPES
AND VENTING COMPONENTS.
NOTE: DXV-35 DEEP TIMBER FIREPLACES INCLUDE THE EXHAUST
RESTRICTOR DAMPER MECHANISM. IN ORDER TO CONVERT THIS FIREPLACE
TO VENT OUT THE REAR, THIS DAMPER MECHANISM MUST BE REMOVED.