MENDOTA GAS DIRECT VENT FIREPLACE with Premium Texture Fiber Logs Combustion System Model DXV-35 DT3-PF2-LX INSTALLATION & OPERATING INSTRUCTIONS NO. PF2-LX-0113 WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
FOR YOUR SAFETY READ BEFORE LIGHTING POUR PLUS DE SÉCURITÉ, LIRE AVANTD'ALLUMER WARNING Do not operate this appliance with the glass removed, cracked or broken. A licensed or qualified person should do replacement of glass. Attention. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas enplace, est craqué ou brisé. Confiez leremplacement du panneau à untechnicien agréé.
DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep MINIMUM FRAMING DIMENSIONS: 37-1/8” WIDE x 31-1/2” HIGH X 16” DEEP 2 2 GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 456 in . Actual Glass size is 580 in . MANTEL ALLOWANCE: 8” Deep Mantel at 14” Above Top Convection Opening VENT SYSTEM ALLOWANCE: Top Vent Only. 12” Vertical Minimum with 6” max horizontal. 55 feet Vertical Maximum.
TABLE OF CONTENTS FOR YOUR SAFETY READ BEFORE LIGHTING ................................................................................................................. 1 DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION ......................................................................................... 2 INITIAL STARTUP ADVICE .................................................................................................................................................... 2 TABLE OF CONTENTS ........
SPECIFICATIONS MODEL DXV-35 DT3 INPUT RATES (Btu/Hr) NAT. GAS LP GAS High Fire 33,000 33,000 Adjustable to - Low Fire 10,000 13,000 NOTE: LP CONVERSION KIT #HA-30-00501 MUST BE PURCHASED SEPARATELY TO BURN LPG. MAIN ORIFICES…REAR BURNER: #44 NAT. GAS [3/64” L.P. GAS] – FRONT BURNER: #49 NAT. [3/64” LP] OVERALL EFFICIENCY Exceeds D.O.E. Efficiency Requirements (A.F.U.E.) For Direct Vent Wall Heaters. 78.5% Steady State Efficiency CO-AXIAL DIRECT VENT FLUE ....
5
Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common Wealth of Massachusetts only. a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes and where the side wall exhaust vent termination is less than seven (7) feet above grade, the following requirements shall be satisfied: 1.
SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instructions may result in a possible fire hazard and will void the warranty. Any safety screen or guard removed for servicing must be replaced before operating this appliance. DO NOT USE this appliance if any part has been under water.
CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of beauty and interest in your home. The Mendota Gas Fireplace is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace.
GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly efficient system brings in outside air for combustion and efficiently heats and re-circulates room air. The Mendota system maintains high air quality, maximizes efficiency and assures proper operation in today's "tight" homes. SAFETY AND STRUCTURAL CONCERNS This Fireplace must be installed and serviced by a Mendota approved service person.
VENT OPTIONS DISCUSSION This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY and ICC brands of coaxial pipe off the top. Use only Mendota specified vents and vent caps when installing your fireplace. Closely follow venting locations, directions and requirements provided in this Manual. Observe the restrictions related to vent position on exterior of home. Make certain that all vent pipe sections are fully twist-locked and leak-proof.
GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fireplace. Be sure the gas supplier or plumber carefully checks for correct gas pressure and gas line sizing when installing the fireplace. It is critical to carefully check for gas leaks when hooking up the fireplace -- check with soap & water solution. Be sure to install "approved" flex gas line with brass-to-brass fittings to prevent gas leaks at connections.
GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Problems such as changes in flame color or flame height, pilot or burner outages, intermittent operation, changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure or improper gas pressure at the time of the installation.
EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 2: Exterior Vent Locations ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF VENT CAP ∨ - Vent Terminal A= ∧ - Air Supply Inlet ≡ - Area where terminal is not permitted Clearance above grade, veranda, porch, deck, or balcony (*12 inches (30 cm) minimum). Vinyl surfaces require 24” min. Clearance to window or door that may be opened (*12 inches (30 cm) minimum.
GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using Amerivent, Duravent, Selkirk Metalbestos, Security Chimney or ICC Brand venting systems.
GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements. The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the absence of local codes, the installation must conform to the most current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54.
outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are allowed. On LOW FIRE (front burner only), you may operate continuously during power outage. MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE SPECIFICATIONS & CLEARANCES WARNING: Do not cover the 2” faceplate border of the unit with combustible materials. 26 1/2 37 7/16 22 5/16 6"MIN. 10 3/4 11 1/8 1"MIN.
TOP FLUE VENTING COMPONENTS ITEM 1 1 1 1 2 3 4 5 9 10 10 11 12 13 14 15 DESCRIPTION 12" VENT STACK 24" VENT STACK 36" VENT STACK 48" VENT STACK 90ºGALVANIZED ELBOW 45º GALVANIZED ELBOW ADJUSTABLE WALL THIMBLE 6" or 7” PIPE ATTIC INSULATION SHIELD 12" ROOF FLASHING (0/12 TO 6/12) ROOF FLASHING (7/12 TO 12/12) STORM COLLAR VERTICAL VENT CAP SUPPORT BAND HORIZONTAL VENT CAP FIRESTOP SPACER Figure 5: Flue Venting Components o o Using 45 elbows in place of a 90 elbow requires 22" minimum opening to center.
FLUE VENTING ALLOWANCE CHART NOTE: FOR LP GAS & HIGH ALTITUDE, SEE PG. 19 NOTE: FOR LPG AND HIGH ALTITUDE APPLICATIONS, SEE PAGE 19. Figure 6: DXV35 Vertical & Horizontal Vent Requirements NOTE: 12” MINIMUM VERTICAL PIPE CAN BE USED IF NO HORIZONTAL VENT SECTIONS GREATER THAN 6” (or 7”) ARE USED. ALL OTHER INSTALLATIONS MUST FALL WITHIN ABOVE SHADED AREA.
L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION L.P. GAS OR HIGH ALTITUDE (ABOVE 4,000 FT. BUT BELOW 7500 FT.) WALL THIMBLE REQUIRED 6" COAX (MIN.) 45° COAX TERMINATION CAP 45° COAX VENT 12" COAX (MIN.) 22" (MIN.) 49 1/4" (MIN.) 85-03-00531 15 1/2" Figure 7: LP MINIMUM VENT For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in place of 90° elbows. NOTE: This requires 22” minimum height to center of vent cap.
MINIMUM RISE THROUGH-THE-WALL VENTING: The minimum vertical rise for vent installation through the wall is 16 1/4" from the top of the fireplace to the centerline of the 90ºelbow in installations where only a 6” (or 7”) horizontal vent section is used (refer to chart on PG.16 when using horizontal sections). NOTE: We recommend always using the most vertical rise the installation will allow. This maximizes efficiency and flame appearance.
VENTING COMPONENTS LIST MENDOTA # 45-01-00186 45-01-00187 45-01-00188 45-01-00189 45-01-00190 45-01-00191 45-01-00192 45-01-00193 45-01-00194 45-01-00195 45-01-00196 45-01-00197 45-01-00198 45-01-00199 45-01-00200 45-01-00201 45-01-00202 45-01-00203 45-01-00204 45-01-00206 45-01-00207 45-01-00208 45-01-00209 45-01-00210 45-01-00211 45-01-00212 45-01-00213 45-01-00214 45-01-00215 45-01-00216 45-01-00217 45-01-00218 45-01-00219 45-01-00220 45-01-00224 45-01-00225 45-01-00226 DESCRIPTION 7" LENGTH 12" LENGTH
ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. For other venting configurations within these maximum limits, see Figure 6, PG. 18. NOTE: All horizontal runs of vent pipe must be level or have a ¼" rise for every 1' of run toward the termination. Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire.
VERTICAL THROUGH-THE-ROOF VENTING The maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a run of a maximum of 55 ft. The vent system must be supported every 3 feet using Support Straps. Maintain 1" air space clearances on all sides of vent components that are positioned vertically and 3” above horizontal pipe sections and components. THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON. 1. 2. 3. 4.
DOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit.: To Unlatch Glass Frame Latches: 1. Insert Glass Latch Tool into hole in latch (two latches exist at top of glass frame). 2. Pull Glass Latch Tool outward about 3/8”. 3. Rotate Glass Latch Tool 90 degrees. 4. Slowly Release Glass Latch Tool. 5.
GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT DO NOT substitute other manufacturer's materials or components. DO NOT operate unit with cracked, broken or missing glass. DO NOT abuse the glass door by striking the glass, slamming the door shut, etc WARNING Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or damaged glass. WARNING Do not operate this appliance with the glass removed, cracked or broken.
DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET. CAUTION: LOGS ARE FRAGILE, HANDLE LOG PIECES WITH CARE. Carefully unpack 9-piece log set, bag of coals and bag of inswool. NOTE: Logs are very fragile, handle with care. Break packaging foam if log pieces are trapped within foam.
PLACE LOG #1 (REAR LOG) ON REAR SHELF BEHIND REAR BURNER. SLIDE LOG TO RIGHT UNTIL LOG TOUCHES RIGHT SIDE BRICK PANEL. PUSH LOG BACK SO IT TOUCHES REAR BRICK PANEL. THIS LOG IS RECOMMENDED TO BE PUSHED TO THE FAR RIGHT SIDE.
LOG #2 LOG# 1 LOG #2 PLACE LOG #2 BETWEEN THE TWO BURNERS AND SLIDE TO THE RIGHT UNTIL THE CURVATURE IN THE FRONT BURNER CONTACTS THE CURVATURE ON THE RIGHT FRONT TIP OF LOG #2. PUSH LOG #2 DOWN TO INDENT THE BOTTOM WITH THE TWO BURNER MOUNTING SCREW HEADS. LOG #2 MUST NOT ROCK ON TOP OF THE SCREW HEADS. LOG #2 MUST BE STABLE. LOG #2 (MID EMBER BED) SITS BETWEEN REAR AND FRONT BURNER, FLAT DOWN ON THE SURFACE OF THE BURNER AIRBOX.
LOG# 3 BURNER LOG# 3 LOG# 3 LOG# 1 LOG #2 LOG #3 MUST LEAVE CLEARANCE FOR THE REAR BURNER PORTS. SOME ROTATIONAL FLEXIBILITY IS ALLOWED FOR THE REAR END OF THIS LOG TO ROTATE TOWARDS LOG #2. HOWEVER, LOG #3 SHALL NEVER SIT ON TOP OF THE REAR BURNER PORTS. DOING SO WILL LEAD TO SOOT CREATION. PLACE LOG #3 (LEFT LOG) ON TOP OF THE RECTANGLE AIR SHUTTER BOX ON THE LEFT SIDE. LOG #3 HAS A RECTANGULAR NOTCH ON ITS BOTTOM SIDE THAT ALLOWS THE LOG TO SIT SQUARELY ON TO OF THE BOX.
LOG #4 REAR TIP OF LOG #4 MUST SIT ON TOP OF LOG #2, HERE. LOG #2 LOG# 4 LOG# 1 LOG #4 (RIGHT LOG) HAS A HOLE FOR THE PIN ON LOG #2. INSERT PIN IN LOG #2 INTO HOLE IN LOG #4. SET RIGHT END OF LOG #4 ON TOP OF THE FIRST GRATE BAR ON THE FAR RIGHT SIDE. SOME ROTATIONAL FLEXIBILITY IS ALLOWED TO LOG #4 AROUND THE PIN AND HOLE. HOWEVER, DO NOT ROTATE REAR END OF LOG OUTWARD. ROTATE INWARD ONLY IF DESIRED.
LOG# 3 LOG# 5 PUSH LOG #5 BACK SO ITS REAR END TOUCHES THE REAR BRICK PANEL. THE V-NOTCH BETWEEN THE TWO BRANCHES MUST SIT DIRECTLY ON TOP OF THE REAR BURNER’S LEFT SIDE PORTS AND MUST ALLOW THE FLAMES TO RISE INTO THE V-NOTCH IN THIS LOG. LOG #5 (LEFT TOP LOG) SITS ON THE LEFT SHOULDER OF LOG #1 AND ITS TWO BRANCHES SIT ON TOP OF LOG #2 AND LOG #3. LOG #5 HAS A HOLE THAT ALIGNS WITH THE LEFT SIDE PIN ON LOG #1.
LOG# 1 LOG #2 LOG# 4 LOG# 6 LOG# 4 LOG# 6 SOME ROTATIONAL FLEXIBILITY IS ALLOWED FOR LOG #6. THE POSITION OF LOG #4 WILL LIMIT THE ROTATION OF LOG #6. PLACE LOG #6 ON TOP OF LOG #1’S PIN. THE OTHER END OF LOG #6 SITS ON TOP OF LOG #2 AS SHOWN, BELOW. LOG #6 (RIGHT TOP LOG) SITS ON TOP OF LOG #1 USING THE PIN THAT IS ON THE RIGHT SIDE OF LOG #1. LOG #6 HAS A HOLE IN ITS BACK-SIDE TO MATE WITH THIS PIN.
LOG# 4 LOG# 7 LOG# 7 LOG# 4 LOG #7 REST ON TOP OF THE FRONT BURNER’S REAR VISIBLE EDGE AND ON TOP OF LOG #4. THIS LOG IS DESIGNED TO HIDE THE PILOT LIGHT. PLACE THIS LOG SO IT PROVIDES CLEARANCE TO ALL BURNER FLAMES AND PILOT FLAMES, YET POSITIONED TO HIDE THE PILOT FLAMES.
LOG# 8 LOG# 2 LOG# 2 2ND BAR LOG# 8 LOG# 2 DO NOT PINCH FRONT BURNER PORTS WITH LOG #8. ATTEMPT TO POSITION LOG #8 AS SHOWN HERE FOR THE BEST GLOW EFFECT AND REALISTIC LOOK. PLACE LOG #8 ( LEFT FRONT TWIG) IN THE POSTION SHOWN HERE. LOG #8 SITS ON TOP OF LOG #2 AND RESTS AGAINST THE GRATE BAR (2ND FROM LEFT).
USING A TOOTH BRUSH, BRUSH INSWOOL (GLOWING EMBERS) RANDOMLY OVER LOG #2, THE COALS AND IN AREAS WHERE YOU WISH TO SEE GLOWING EMBER EFFECTS. SCATTER SMALL COALS ON THE FLOOR AND BETWEEN THE LOG GRATE’S HORIZONTAL BAR AND THE FRONT BURNER. A FEW COALS MAY SIT ON TOP OF THE FRONT BURNER TUBE BUT AVOID PLACING TOO MANY COALS ON TOP OF THE FRONT BURNER PORTS. LOG #9 (RIGHT FRONT CHUNK) IS TO BE PLACED AT A SEVERE ANGLE AGAINST THE HORIZONTAL GRATE BAR AND FLOATING OVER THE FRONT BURNER PORTS.
COMPLETED LOG SET ASSEMBLY
The following Check Off Lists must be completed prior to final operation of the Fireplace, or manufacturer's warranty and liabilities will be voided: INSTALLATION CHECK OFF LIST q Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved person in accordance with instructions. All joints must be secured, "twistlocked" and leak-proof. 1000ºF sealant use is recommended on the inner pipe joints of DuraVent pipe sections.
BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Failure to follow the instructions may result in property damage, bodily injury, or even death. An Optional Wall Holder (#HA-78-00205) for the Remote Transmitter is available. Contact you dealer. Remote Control Transmitter Functions NOTE: The Receiver will “beep” once every time a Remote Transmitter Key is pressed, signaling that the command has been received.
REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will show all active icons on the screen. 2. Select the Thermostat Mode by pressing the Thermostat Key: OFF (meaning Manual Mode), ON (meaning normal Thermostat) or Smart (meaning Smart Mode). a. In OFF (Manual Mode), the appliance will ignite and start on HI. b. In ON (Normal Thermostat Mode), the appliance will only ignite if the Set Temperature is greater than the Room Temperature. c.
o o TEMPERATURE INDICATOR ( F or C) 1. Press the ON/OFF Key and Turn Off the Fireplace. 2. Simultaneously, Press both the MODE Key and the Thermostat Key. o 3. Look at the LCD display to verify that your desired indicator ( F or o C) is being displayed. If not, repeat step 2. KEY LOCK FUNCTION To prevent unsupervised children from operating the fireplace, a KEY LOCK function is provided with this remote control system.
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. 1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the Master On/Off switch is toggled to the ON position. 2.
IPI/STANDING PILOT SYSTEM INFORMATION REMOTE CONTROL 4.5V (three 1.5V AAA batteries) o o 32 – 122 F (0 – 50 C) 315 MHz Supply voltage Ambient temperature ratings Radio Frequency ATTENTION! • • • • The transmitter and receiver are RADIO FREQUENCY DEVICES. Turn off the main gas supply of the appliance during installation or maintenance of the receiver. Toggle the Master Switch to OFF during installation or maintenance.
Backup Batteries Backup Batteries are to be installed in the Battery Pack located on the right side of the Courtesy Panel beneath the glass frame. The life span of the backup batteries depends on the quality of the batteries used and how long the batteries have been installed in the Battery Pack. With good quality batteries, you can expect proper operation for periods in excess of 2 weeks. These batteries are only utilized during power outages.
BLOWER OPERATION AND WIRING WARNING: The Electrical Junction box within this appliance must be connected to a grounded LIVE power circuit. No switches, Light Dimmers or Fan Speed Control Devices are allowed within the same electric circuit as this appliance. Connect only to a LIVE electrical power supply that is not controlled by any other switching device. Dual blowers are provided as standard equipment with this DXV35 DT3 Fireplace. The dual blowers have an air output rating of 210 CFM (in free air).
TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE SYMPTOM 1. Thin black coating (soot) forms on viewing glass. PROBABLE CAUSES A. Incorrect gas pressure B. Not enough combustion air CORRECTIVE ACTION Have gas supplier check for correct gas pressure (7" W.C. Nat. Gas; 12" W.C. LP Gas). If sooting continues open air shutter on burner (see "Gas Flame Adjustment" below). If sooting still continues, shut off unit and call Mendota service person.
CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Fireplaces comply with UL Standards for maximum surface temperatures on exposed combustible surfaces adjacent to the unit. The Maximum allowable surface temperature is 117° F. over ambient (room) temperature. Thus, if a room is 70° – 80° the exposed combustible surfaces immediately surrounding the Fireplace can have a surface temperature as high as 187° F. – 197° F. (Too hot to touch).
MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approved service person. NOTE: Any adjustments to burner, pilot or logs must be done by a qualified Mendota service person. A. Replace backup batteries at least 2 times annually. Replace them when the Day Light Savings Time changes. B. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or damage. C.
WIRING SCHEMATICS Note: The DXV35-DT3-LX ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power outage, the Battery Pack power is utilized.
NATURAL TO LP GAS CONVERSION INSTRUCTIONS Kit # HA-30-00507 Mendota Model DXV35 DT3 This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
5. Using a ½” deep well socket wrench, remove Front and Rear Orifices. 6. Thread a new 3/64” drilled orifice to both Front and Rear Orifice mounting brass fittings. Tighten down orifices. 7. Locate Pilot Light on left side of firebox. While holding the pilot base body with large vice grips tightly, loosen Pilot Light’s hex shape base using a ½” open end wrench. Rotate counter clock-wise ¼ turn to loosen. 8. Pilot arrives from the factory set for NG.
10. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” minimum. 11. Install both rear and front burners in their original locations and positions and secure down using screws you removed earlier. LOOSEN SCREW ROTATE SHUTTER OPEN -1/4" MINIMUM- FRONT BURNER SHUTTER ADJUSTMENT 12.
INSTALLING THE LP PRESSURE REGULATOR WARNING: READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY BEFORE YOU ATTEMPT THE CONVERSION. FAILURE TO FOLLOW ALL INSTRUCTIONS WILL RESULT IN A LEAK OR OVERFIRING OF THE APPLIANCE AND CAN LEAD TO AN EXPLOSION OR A FIRE HAZARD. 1. Remove the Courtesy Access Panel mounted behind the lower grill and lay down gently without disconnecting any wires of internal components. WARNING: DO NOT FORCE.
LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the outer left side of the fireplace. A qualified installer shall take pressure measurements at these ports to verify and set the correct gas pressures during the LP Kit installation and before fascia materials are installed over the front of this fireplace.
CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS Once the conversion to LPG and all the above steps have been completed, light the main burners. Press the On/Off button on Remote Transmitter. Once the pilot light is lit and established, Main burner should now light IMMEDIATELY and flame should not "lift" off burner.
REPLACEMENT PARTS MENDOTA GAS DXV-35 DT3 FIREPLACE PART NO DESCRIPTION PART NO DESCRIPTION 65-02-00103 TADPOLE GLASS GASKET (106”) 05-04-00065 PILOT ASS'Y. NAT. 65-06-00463 GLASS – FLAT HA-30-00415 DOOR FRAME ASSEMBLY – FLAT HA-30-00507 LP KIT 35-01-00600 DEEP TIMBER III LOG SET 35-01-00240 COALS 12 OZ BAG 65-14-00044 REAR ORIFICE (NAT. GAS) # 44 35-01-00239 GLOWING INSWOOL 65-14-00049 FRONT ORIFICE (NAT.
MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION The following Designer Fronts are available for the DXV-35 Fireplace: 1. Andover, Bentley Arched Door Kit or Prairie Rectangular Door kit with Fire screen with optional Overlays as listed below: a. Black Overlay b. Pewter Overlay c. Antique Copper Overlay d. 24K Gold 2. Wellington Fire screen Front 3. Black or 24K Gold Victoria Filigree 4. Black or 24K Gold Tuscany Filigree 5. Millennia Flat Grills in four optional color schemes as listed below: a.
Information specific to the installation of Millennia Flat Grills, Victoria Filigrees and Tuscany Filigrees The Millennia Flat Grills, Victoria Filigree and Tuscany Filigree are designed to be “inside-fit” trim kits. All of these trim kits fit within the inner perimeter of the Fireplace’s Faceplate and remain flush within the Faceplate’s front surface, see Figure below.
RATING LABEL REPRESENTATION DXV35 DT3 58
THIS PAGE LEFT BLANK INTENTIONALLY 59
THIS PAGE LEFT BLANK INTENTIONALLY 60
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Registration to Mendota.
TAPE SHUT -------------------------------------------------------------------------------------------------------------------------------------------------------- POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W.
MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY MENDOTA DXV35 DIRECT VENT FIREPLACE INSERT Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Protection and Limited Warranty to the original purchaser of a Mendota FV46 Fireplace, which is limited and used under normal home conditions. STANDARD WARRANTY: JOHNSON GAS APPLIANCE CO.
Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com or www.mendotahearth.