GAS DIRECT VENT FIREPLACE with Premium Fiber Log Set Combustion System Model DXV-45 DT3-PF2- LX INSTALLATION & OPERATING INSTRUCTIONS NO. DXV45-DT3-LX-PF2-0113 WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Do not operate this appliance with the glass removed, cracked or broken. A licensed or qualified person should do replacement of glass. Attention. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas enplace, est craqué ou brisé. Confiez leremplacement du panneau à untechnicien agréé. This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.
DXV45 DT3 FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 40-3/8” Wide X 39” High X 19-1/8” Deep MINIMUM FRAMING DIMENSIONS: 41” WIDE x 38-1/8” HIGH X 20” DEEP 2 GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 707.5 in . Actual Glass size is 840 2 in . MANTEL ALLOWANCE: 8” Deep Mantel at 14” Above Top Convection Opening VENT SYSTEM ALLOWANCE: Top Vent Only. 0” Vertical 24” max horizontal. 55 feet Vertical Maximum.
Contents FOR YOUR SAFETY READ BEFORE LIGHTING DXV45 DT3 FEATURES - QUICK REFERENCE INFORMATION INITIAL STARTUP ADVICE CONTENTS SPECIFICATIONS BUILDING PERMIT AND INSTALLATION INSPECTION APPROVAL REQUIREMENTS LOCATING THE FIREPLACE AND GENERAL INFORMATION HEATING PERFORMANCE ELECTRICAL REQUIREMENTS: DXV-45 GAS DIRECT VENT FIREPLACE INSTALLATION INSTRUCTIONS GAS SUPPLY REQUIREMENTS GAS PRESSURE REQUIREMENTS EXTERIOR VENT LOCATIONS AND RESTRICTIONS FLUE VENTING INSTRUCTIONS FLUE VENTING REQUIREMENTS FOR NG AND
SPECIFICATIONS MENDOTA, MODEL DXV-45 High Fire - Adjustable to - Low Fire BTUH. (MODEL DXV-45) NAT. GAS BTUH. (MODEL DXV-45) L.P. GAS 45,000 7,500 40,000 5,000 NOTE: LP CONVERSION KIT #HA-42-00225 OR AA-11-01257 MUST BE PURCHASED SEPARATELY FOR THE DXV45 FIREPLACE TO BURN LPG. MAIN ORIFICE: REAR BURNER #38 NAT. GAS-#53 L.P. GAS OVERALL EFFICIENCY SAFETY FRONT BURNER #44 NAT. - #3/64 LP EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.
CONGRATULATIONS! You are the owner of a world class, heat producing, gas, direct vent, sealed combustion fireplace. This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of beauty and interest in your home. The Mendota Gas Fireplace is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace.
LOCATING THE FIREPLACE AND GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly efficient system brings in outside air for combustion, has a separate exhaust vent and efficiently heats and re-circulates room air. The Mendota system maintains high air quality, maximizes efficiency and assures proper operation.
HEATING PERFORMANCE Mendota Gas Built-in Fireplaces are true, high efficiency gas heaters. With its high heat output the Mendota Fireplace will heat a large area of your home if situated to maximize heat circulation. Air movement options for maximizing heat circulation which can be considered are through-the-wall grills or floor grills, the continuous operation of central heating furnace blowers, or ceiling fan. The most efficient method for overall heat distribution is a ceiling fan.
DXV-45 GAS DIRECT VENT FIREPLACE SPECIFICATIONS & CLEARANCES DIRECT VENT COAXIAL PIPE SIZE: 5" I.D. X 8" O.D. 51 7/16 51 7/16 FIGURE 1: Specifications & Clearances HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements. The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the absence of local codes, the installation must conform to the most current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54.
10
GAS SUPPLY REQUIREMENTS Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fireplace. Be sure the gas supplier or plumber carefully checks for correct gas pressure and gas line sizing when installing the fireplace. It is critical to carefully check for gas leaks when hooking up the fireplace -- check with soap & water solution. Be sure to install "approved" flex gas line with brass-to-brass fittings to prevent gas leaks at connections.
GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Problems such as changes in flame color or flame height, pilot or burner outages, intermittent operation, changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure or improper gas pressure at the time of the installation.
EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 3: Exterior Vent Locations NOTE: ALL MEASUREMENTS TO BE TAKEN FROM CENTER LINE OF VENT CAP ∨ - Vent Terminal A= B= C= D= E= F= G= † ‡ * 13 ∧ - Air Supply Inlet Clearance above grade, veranda, porch, deck, or balcony (*12 inches (30 cm) minimum). Vinyl surfaces require 24” min. Clearance to window or door that may be opened (*12 inches (30 cm) minimum.
FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using DuraVent or Amerivent or Security venting system.
FLUE VENTING REQUIREMENTS FOR NG AND LPG NOTE: IF A 90º ELBOW IS CONNECTED DIRECTLY TO THE FLUE OULET, THE MAXIMUM HORIZONTAL DISTANCE FROM THE FLUE OUTLET CENTERLINE TO THE OUTSIDE WALL IS 24". A maximum of three (3) 90ºelbows are allowed per installation. o o Each 90º elbow USED, after the first 90 elbow, reduces the maximum horizontal distance by 3'. Each 45 elbow o USED, after the first 90 elbow, reduces the maximum horizontal distance by 1-1/2’.
5"/ 8"FLUE VENTING COMPONENTS FOR NG AND LPG ITEM # 1 1 1 1 2 3 4 5 9 10 10 11 12 13 14 15 16 17 16 PART # DESCRIPTION 45-01-00222 45-01-00223 45-01-00224 45-01-00225 45-01-00228 45-01-00227 45-01-00229 45-01-00226 45-01-00239 45-01-00236 45-01-00237 45-01-00238 45-01-00230 45-01-00234 45-01-00231 45-01-00235 45-01-00221 AA-11-00458 12" VENT STACK 5" / 8" 24" VENT STACK 5" / 8" 36" VENT STACK 5" / 8" 48" VENT STACK 5" / 8" 90ºGALVANIZED ELBOW 5" / 8" 45º GALVANIZED ELBOW 5" / 8" ADJUST.
Adjustable– telescoping – pipe sections must be sealed using 1000° MILLPAK SILICATE STOVE MASONRY SEALANT (part #65-06-00909). HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
A-1 MINIMUM RISE THROUGH-THE-WALL VENTING FOR NG AND LPG HEAT SHIELD #AA-11-00458 HEAT SHIELD AA-11-00458 Y WARNING: ALWAYS USE HEAT SHIELD (#AA-11-00458) WHEN EXTERIOR WALL COVERING IS MADE OF VINYL, WOOD OR OTHER COMBUSTIBLE MATERIALS. HEAT SHIELD (#AA-11-00458) IS INCLUDED WITH THE DXV45 FIREPLACE. IMPORTANT: REFER TO DRAWINGS ON PAGE 12-14 WHILE FOLLOWING THESE INSTRUCTIONS.
A-2 ELEVATED RISE THROUGH-THE-WALL VENTING FOR NG AND LPG The minimum vertical rise from top of fireplace is 48 in. when used with the maximum horizontal run of 16 ft. For other venting configurations within these maximum limits see pg. 15. NOTE: All horizontal runs of vent pipes must have a ¼" rise for every 1' of run toward the termination. Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire.
B - 1 VERTICAL THROUGH-THE-ROOF VENTING FOR NG AND LPG The maximum vertical run of vent pipe is 36 ft. from the top of the fireplace. The fireplace will support a run of a maximum of 36 ft. Maintain 1" air space clearances on all sides of vents (2" above horizontal vents). IMPORTANT: REFER TO DRAWING ON PAGE 10 & 11 WHILE FOLLOWING THESE INSTRUCTIONS. Place the fireplace in its desired location. Drop a plumb bob from the ceiling to the center position of the fireplace flue exit.
Height "*H" of top of vent cap can be determined as follows: ROOF PITCH FLAT to 6/12 7/12 to 9/12 10/12 to 12/12 13/12 to 16/12 17/12 to 21/12 "H" DIMENSION FEET METERS 2 .6 2 .6 4 1.2 6 1.8 8 2.4 Complete installation with storm collar and vent cap. HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION The following Designer Fronts are available for the DXV-45 Fireplace: 1. Andover Arched Door Kit with Firescreen with optional Overlays as listed below: 2. Black Andover Overlay 3. Pewter Andover Overlay 4. Antique Copper Andover Overlay 5. Gold Andover Overlay 6. Prairie Rectangular Door Kit with Firescreen with optional Overlays as listed below: 7. Black Prairie Overlay 8. Pewter Prairie Overlay 9. Antique Copper Prairie Overlay 10. Gold Prairie Overlay 11.
Hearth Protection Pad Installation Information when planning to Install the Andover or Prairie Fronts Any hearth protection pad installed in front of the DXV-45 Fireplace must be designed, built and installed so that the hearth protection pad’s top surface is flush with the bottom-most surface of the DXV45 Fireplace. See the diagram to the right.
DOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit.: To Unlatch Glass Frame Latches: 1. Insert Glass Latch Tool into hole in latch (two latches exist at top of glass frame). 2. Pull Glass Latch Tool outward about 3/8”. 3. Rotate Glass Latch Tool 90 degrees. 4. Slowly Release Glass Latch Tool. 5.
GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT DO NOT substitute other manufacturer's materials or components. DO NOT operate unit with cracked, broken or missing glass. DO NOT abuse the glass door by striking the glass, slamming the door shut, etc WARNING Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or damaged glass. WARNING Do not operate this appliance with the glass removed, cracked or broken.
DXV45 COAL BED AND LOGS INSTALLATION Carefully unpack the shipping boxes containing the coal bed sections and logs and remove them gently from the foam packing. 10 Log pieces, one 24 oz bag of small coals and one bag of inswool/Rockwool are included. Lay out the log pieces on a soft flat surface and arrange them according to the diagram, below, to aid you in through the installation process. DXV45-DT3 LOG SET PARTS IDENTIFICATION Also included but not shown here are a 24 oz.
DXV45-DT3 LOG SET INSTALLATION INSTRUCTIONS 1. Locate Fiber Coal Bed “A”. This Fiber Coal Bed installs between the front burner and the front of the rear burner tube as shown below. 2. The Fiber Coal Bed “A” is placed directly behind the front burner. The Coal Bed ‘s front edge must touch back edge of front burner tube. A FIBER COAL BED “A” 3. Slide Fiber Coal Bed “A” to the left as far as possible. The left edge of this Coal Bed shall touch propagation leg of front burner tube.
C LOG “C” Holes in bottom of Log “C”. 9. Identify Log “C”. Back left log. 10. Locate holes on bottom of log. 11. Place log “C” onto the 2 pins on left-side behind the rear burner as shown. 12. D 13. Identify Log “D”. This log will be installed between the front and back of the rear burner tube as shown below. Note that on the left end of log “D” is a curvature [along the bottom edge]. LOG “D” 14. 15. The curvature on the bottom left side sits on top of the rear burner’s inlet tube.
F E 18. Identify Log “G” and locate the hole at its bottom surface. Log “G” will be installed on the left side of the fireplace, with the hole on the bottom of the log setting on the left pin in log “D”. 16. Identify Log “E” and Log “F”. Log “E” rests on left side of the T-propagation tube . Log “E”’s left edge rests against the front burner inlet tube, at floor level. 17. Log “F” sits on the firebox floor and against the left side of the inlet tube on the front burner.
I 22. Identify Log “I”. Log “I” will be installed in the middle of the fireplace, with the hole on the bottom of the log setting on the middle pin in log “D”. 2” gap 23. Once Log “I” is pinned to the middle pin in Log “D”, rotate FRONT –MOST TIP of Log “I” so that it is 2 inches to the left of the Right-Most Grate Bar. 24. 25. 30 Place Log “J” as shown here. You will find that it sits down well and “selfpositions” on the ember bed. You may rotate the position of this log as it suites your taste.
Place small coals between Firebox Front and front Burner. Pile the coals higher near the Front burner to build height. Any excess coals should be spread on the far left and far right sides of firebox to extend the coal bed effect. A couple of coals may be place behind front burner tube on Ember Bed “A” but sparsely. Avoid covering front burner tube’s gas ports. Hold a clump of Inswool/ Rockwool in one fist tightly with a small portion protruding out.
FINAL LOG SET, COALS AND INSWOOL LAYOUT RECOMMENDED PATTERN Note: Some minor adjustment to coals locations may me necessary on LP gas units. Also, some adjustment to brushed inswool thickness may be necessary if inswool brushed over middle or rear burner are too thick and heavy and impede combustion air flow to burner. COMPLETED LOGS AND COAL BED ASSEMBLY EVALUATION See the picture, shown above. This picture shows the recommended log positions. Slight variations in the position of each log is allowed.
The following Check Off Lists must be completed prior to final operation of the Fireplace. Failure to do so may result in abnormal function or dangerous operation. Ignorance of these guidelines can lead to property damage, personal injury or death and the manufacturer’s warranty and liabilities will be voided: Keep a record of these Check OFF guidelines for future reference. Mendota may request a certified copy of these Check OFF lists to verify compliance to these printed guidelines.
BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Failure to follow the instructions may result in property damage, bodily injury, or even death. An Optional Wall Holder (#HA-78-00205) for the Remote Transmitter is available. Contact you dealer. Remote Control Transmitter Functions NOTE: The Receiver will “beep” once every time a Remote Transmitter Key is pressed, signaling that the command has been received.
REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will show all active icons on the screen. 2. Select the Thermostat Mode by pressing the Thermostat Key: OFF (meaning Manual Mode), ON (meaning normal Thermostat) or Smart (meaning Smart Mode). a. In OFF (Manual Mode), the appliance will ignite and start on HI. b. In ON (Normal Thermostat Mode), the appliance will only ignite if the Set Temperature is greater than the Room Temperature. c.
TEMPERATURE INDICATOR (oF or oC) 1. Press the ON/OFF Key and Turn Off the Fireplace. 2. Simultaneously, Press both the MODE Key and the Thermostat Key. o 3. Look at the LCD display to verify that your desired indicator ( F or o C) is being displayed. If not, repeat step 2. KEY LOCK FUNCTION To prevent unsupervised children from operating the fireplace, a KEY LOCK function is provided with this remote control system. To activate the KEY LOCK function, simultaneously press the “MODE KEY” and the “UP KEY”.
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. 1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the Master On/Off switch is toggled to the ON position. 2.
IPI/STANDING PILOT SYSTEM INFORMATION Supply voltage Ambient temperature ratings Radio Frequency REMOTE CONTROL 4.5V (three 1.5V AAA batteries) o o 32 – 122 F (0 – 50 C) 315 MHz ATTENTION! • • • • The transmitter and receiver are RADIO FREQUENCY DEVICES. Turn off the main gas supply of the appliance during installation or maintenance of the receiver. Toggle the Master Switch to OFF during installation or maintenance.
Backup Batteries Backup Batteries are to be installed in the Battery Pack located on the right side of the Courtesy Panel beneath the glass frame. The life span of the backup batteries depends on the quality of the batteries used and how long the batteries have been installed in the Battery Pack. With good quality batteries, you can expect proper operation for periods in excess of 2 weeks. These batteries are only utilized during power outages.
BLOWER OPERATION AND WIRING WARNING: The Electrical Junction box within this appliance must be connected to a grounded LIVE power circuit. No switches, Light Dimmers or Fan Speed Control Devices are allowed within the same electric circuit as this appliance. Connect only to a LIVE electrical power supply that is not controlled by any other switching device. Dual blowers are provided as standard equipment with this DXV45 DT3 Fireplace. The dual blowers have an air output rating of 210 CFM (in free air).
TROUBLESHOOTING MENDOTA GAS DXV FIREPLACE SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating (soot) forms on viewing glass. A. Incorrect gas pressure Have gas supplier check for correct gas pressure (7" W.C. Nat. Gas; 11" W.C. LP Gas). If sooting continues open-air shutter on burner (see "Gas Flame Adjustment" below). If sooting still continues, shut off unit and call Mendota service person. NOTE: To clean glass - remove glass and wipe glass with cloth or paper towel. B.
CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURES Mendota Fireplaces comply with UL Standards for maximum surface temperatures on exposed and embedded combustible surfaces adjacent to the unit. The Maximum allowable surface temperature is 117° F. over ambient (room) temperature on exposed surfaces. Thus, if a room is 70° – 80° the exposed combustible surfaces immediately surrounding the Fireplace can have a surface temperature as high as 187° F. – 197° F. (too hot to touch).
MAINTENANCE ANNUAL MAINTENANCE OF THIS MENDOTA FIREPLACE IS REQUIRED. The following procedures must be performed each year by a Mendota approved service person. NOTE: Any adjustments to burner, pilot or logs must be done by a qualified Mendota service person. A. Replace backup batteries at least 2 times annually. Replace them when the Day Light Savings Time changes. B. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or damage. C.
WIRING SCHEMATICS Note: The DXV45 DT3 ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power outage, the Battery Pack power is utilized.
NATURAL TO LP GAS CONVERSION INSTRUCTIONS Kit # HA-42-00302 Mendota Model DXV45-DT3-LX This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
5. Using a ½” deep well socket wrench, remove Front and Rear Orifices. HINT: PACK SOME SOFT PAPER OR INSWOOL INSIDE DEEP WELL SOCKET TO STOP CAP ORIFICE FROM SLIDING TOO FAR INTO THE SOCKET. 6. Thread a new 3/64” drilled orifice to the Front Orifice mounting brass fitting and new #53 drilled orifice to the Rear Orifice mounting brass fitting. Tighten down orifices. 7. Locate Pilot Light on left side of firebox.
. 10. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” minimum. 11. Install both rear and front burners in their original locations and positions and secure down using screws you removed earlier. 12. Make certain front and rear burners are running parallel to front face of unit and positioned properly so that the pilot light flames are pointed properly towards the burner’s flame propagation ports.
INSTALLING THE LP PRESSURE REGULATOR WARNING: READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY BEFORE YOU ATTEMPT THE CONVERSION. FAILURE TO FOLLOW ALL INSTRUCTIONS WILL RESULT IN A LEAK OR OVERFIRING OF THE APPLIANCE AND CAN LEAD TO AN EXPLOSION OR A FIRE HAZARD. 1. Remove the Courtesy Access Panel mounted behind the lower grill and lay down gently without disconnecting any wires of internal components. WARNING: DO NOT FORCE.
LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the outer left side of the fireplace. A qualified installer shall take pressure measurements at these ports to verify and set the correct gas pressures during the LP Kit installation and before fascia materials are installed over the front of this fireplace.
REPLACEMENT PARTS MENDOTA DXV-45 DT3 FIREPLACE PART NO DESCRIPTION PART NO DESCRIPTION 65-02-00103 GLASS GASKET 05-04-00065 PILOT ASS'Y. NAT. 65-06-00658 HA-42-00210 GLASS - FLAT DOOR FRAME ASS'Y. – FLAT 35-01-00320 LOG SET 35-01-00239 35-01-00302 GLOWING INSWOOL FIREBRICK KIT HA-42-00302 65-14-00038 65-14-00044 65-14-00053 65-14-00364 LP KIT REAR ORIFICE (Nat. Gas) # 38 FRONT ORIFICE (NAT.
LISTING LABEL, RATING PLATE REPSENTATION LISTED DIRECT VENT GAS FIREPLACE HEATER POÊLE AU GAZ HOMOLOGUE’, A AÉRATION DIRECTE NOT FOR USE WITH SOLID FUEL (NE DOIT PASÉ UTILISÉ AVEC UN COMBUSIBLE SOLIDE) Manufactured by (Fabriqué par): JOHNSON GAS APPLIANCE CO. CEDAR RAPIDS, IOWA CERTIFIED FOR CANADA HOMOLOGUÉ POUR LE CANADA Tested to (Testé aux normes) ANSI Z21.88-2005 • CSA 2.33-2005 • CAN/CGA 2.17-M91 and ANSI Z21.50-1996.
THIS PAGE LEFT BLANK INTENTIONALLY 52
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Registration to Mendota.
TAPE SHUT -------------------------------------------------------------------------------------------------------------------------------------------------------- POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W.
MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY MENDOTA DXV45 DIRECT VENT FIREPLACE INSERT Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Protection and Limited Warranty to the original purchaser of a Mendota FV46 Fireplace, which is limited and used under normal home conditions. STANDARD WARRANTY: JOHNSON GAS APPLIANCE CO.
Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division www.johnsongas.com or www.mendotahearth.