User manual

Functional Description
MEN Mikro Elektronik GmbH 19
20F302-00 E4 – 2010-12-16
2.2.2 Configuration of the Switch
The F302 loads the following standard configuration for the 8 ports available at the
front of the unit at startup:
Table 4. Default switch configuration at startup
All of the ports are individually configurable using an external dongle, a Telnet or
Secure Shell (SSH) command line interface via the D-Sub service connector or over
Ethernet via SNMP (Version 3) or the unit’s web server interface. For further
information about configuration options please refer to the documentation of the
F302 firmware.
2.3 Service Interface (RS232 / I
2
C)
The service connector features an RS232 UART interface for maintenance
purposes. Further information about maintenance and configuration options is
provided in the documentation of the F302 firmware.
An I
2
C connection is also available to connect an external dongle (available from
MEN) for easy dumping or uploading of configuration data.
Table 5. Pin assignment of the 9-pin D-Sub service interface connector
Setting Default
Duplex mode Full Duplex
Port speed Auto-Negotiate
VLAN (port-based) Off
QoS (Quality of Service) Off
Port mirroring and port monitoring Off
Port trunking Off
Pin Name Description
1GPIO[0]
General purpose I/O 0
Apply active signal for more than 2 seconds:
Reset
Apply active signal for more than 10 seconds:
Reset with restored factory settings
2 RS232_RX RS232 receive data
3 RS232_TX RS232 transmit data
4SCLI
2
C data clock for external dongle
5 GND Ground
6GPIO[1]
General purpose I/O 1
Used for detection of external dongle
7 +3.3V Power supply for external dongle
8SDAI
2
C serial data input/output for external dongle
9 GND Ground
1
6
5
9