User guide
SC35 User Guide Ver 4.8  August 30, 2002  Page 4 of 25 
3.  GENERAL DESCRIPTION 
3.1  SCSI Interface 
An intelligent SCSI controller from NCR, the 53C90A, handles the SCSI 
interface for the SC35. The 53C90A is SCSI-I and SCSI II compliant, and 
automates much of the interface overhead. It has a 16 byte FIFO, a DMA 
interface, and numerous command and control registers. 
The SC35 employs the following attributes: 
1.  Single-ended drivers 
2.  Termination power derived from cable 
3.  Parity on the interface 
4.  "Hard" RESET implemented 
5.  No reservation queuing 
The SC35 has implemented all mandatory SCSI-I and SCSI- II commands 
and several optional commands to enhance functionality. The following is a 
list of commands and their equivalent hexadecimal representation. 
1.  Test Unit Ready  00h    M 
2.  Rezero Unit  01h    O 
3.  Request Sense  03h    M 
4.  Format Unit  04h    M 
5.  Read    08h    M 
6.  Write    0Ah    O 
7.  Inquiry    12h    M 
8.  Reserve Unit  16h    M 
9.  Release Unit  17h    M 
10.  Mode Sense  1Ah    O 
11.  Send Diagnostics  1Dh    M 
12.  Read Capacity  25h    M 
13.  Extended Read  28h    M 
14.  Extended Write  2Ah    O 
15.  Erase    2Ch    O 
16.  Verify    2Fh    O 
Notes:  O = Optional  M = Mandatory 
The implemented messages on the SC35 are as follows: 
1.  Command Complete  00h  Generated 
2.  Extended Message  01h  Both 
3.  Init Detected Error  05h  Received 
4.  Abort    06h  Received 
5.  Message Reject  07h  Generated 
6.  NoOp Message  08h  Received 
7.  Message Parity Error  09h  Received 
8.  Bus Device Reset  0Ch  Received 
9.  Identify    80h  Received 










