4.  GENERAL SPECIFICATIONS 
Interface 
SCSI Compatibility  ANSI X3.131-1994
SCSI Device Type  0 - Direct Access Device 
Maximum Capacity  27648 Mbytes 
Bytes/Block  512 
Bus Width  8 bits 
Termination  Active – on board 
Data Transfer Specifications 
Bus width  1 byte (8 bits) 
Read Transfer Rate  1.5 Mbyte/sec., sustained 
Write Transfer Rate  650 Kbytes/sec sustained 
Data Access time  0.7 msec 
Environmental Requirements 
Operating Ambient Temperature       
  Commercial  0
o
C to +70
o
C 
  Extended  -20
o
C to +75
o
C 
  Industrial  -40
 o
C to +85
 o
C 
Storage Temperature  -55
o
C to +125
o
C Ambient 
Humidity  5% to 95% non-condensing 
Airflow Requirements  none 
Ceiling  no limit 
Mechanical (Full Capacity) 
Length  15.24cm (6.00 in.) 
Width  10.16cm (4.00 in.) 
Max Height  03.68cm (1.45 in.) 
Drive Form Factor  3.5" half height drive 
Mounting Considerations  None (any orientation) 
Max Weight  18.5 ounces (525 grams) 
Power Requirements 
Vcc Supply  +5.00 volts +/- 5% 
Vdd Supply  Not Used 
Power Idle  0.50 watts 
Power Active  0.90 watts 
Power Max  1.10 watts 