User guide
SC35 User Guide Ver 4.8  August 30, 2002  Page 15 of 25 
3.3.10  Mode Sense 
The MODE SENSE (6) command provides a means for a target to report 
parameters to the initiator. It is a complementary command to the MODE 
SELECT (6) command. 
Mode Sense CDB 
A disable block descriptors (DBD) bit of zero indicates that the target may return 
zero or more block descriptors in the returned MODE SENSE data, at the 
target’s discretion. A DBD bit of one specifies that the target shall not return any 
block descriptors in the returned MODE SENSE data. The page control (PC) 
field defines the type of mode parameter values to be returned in the mode 
pages. The page code specifies which mode page to return. 
3.3.11  Send Diagnostics – 1Dh 
The SEND DIAGNOSTIC command requests that the SC35 perform diagnostic 
operations on itself. The only mandatory implementation of this command is the 
self-test feature with the parameter list length of zero.  
Send Diagnostics CDB 