Datasheet
Recommended Operating Conditions
Supply Voltage VCC 4.5 5.5 V
Input High Voltage VIH 0.7VCC VCC + 0.3 V
Input Low Voltage VIL - 0.3 0.8 V
Battery Voltage VBAT 2.37 V
Relative Humidity (non-condensing) HUM 95 %
Absolute Maximum Ratings *
Parameter Symbol Value Unit
Supply Voltage VCC -0.5 to + 6.0 V
Input Voltage VIN -0.5 to VCC + 0.3 (6V max.) V
Output Voltage VOUT -0.5 to + 6.0 V
Operating Temperature ( Commercial ) TOPR -0 to + 70 °C
Storage Temperature ( Commercial ) TSTR -25 to + 70 °C
Operating Temperature ( Industrial ) TOPR -25 to + 75 °C
Storage Temperature( Industrial ) TSTR -40 to + 85 °C
Relative Humidity (non-condensing) HUM 95 (maximum) %
*Comments
Stress above those listed under " Absolute Maximum Ratings " may cause permanent
damage to the products. These are stress rating only. Functional operation of these products
at these or any other conditions above those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for extended
periods may affect product reliability.
DC Electrical Characteristics
(recommended operating conditions unless otherwise noted)
Symbol Parameter Min. Max. Unit Test Conditions
ILI Input Leakage Current -10 10 uA VIN = 0V to Vcc ( Note 3 )
-70 10 uA VIN = 0V to Vcc ( Note 4 )
ILO Output Leakage Current -10 10 uA CE1* = CE2* = VIH or OE* = VIH ,
VI/O = 0V to VCC ( Note 1 )
VOH Output High Voltage 3.8 V IOH = -2mA (Note 2)
VOL Output Low Voltage 0.4 V IOL = 3.2mA ( Note 2 )
VIH Input High Voltage 0.7Vcc Vcc+0.3 V
VIL Input Low Voltage -0.3 0.3Vcc V
ICC Vcc Operating Current 120 mA Min. cycle , IOut = 0mA
ISB Vcc Standby Current 0.1 mA For page 3 & 4, item 9
( CE1*= CE2*= VIH or 0.2 mA For page 3 & 4, item 10
CE1*= CE2*≥VCC - 0.2V ) 0.1 mA For page 3 & 4, item 11,17