4.2
Start screen and
licence file
CELSIUS FDA Version can be started only with a valid
licence file containing a list of equipment
serial numbers which can be accessed with this version. The
licence file called “LICENSE.XML“
is located in the CELSIUS folder and carries a digital signature; it is thus protected against any
alteration.
The
licence file contains also a licence number and optionally an entity name which is included
in the GLP data. The digital signature on the
licence file can be produced only by MEMMERT.
The licence number remains unchanged if the entity name is altered or if additional equip-
ment is purchased, so that all data remain readable.
The digital signature ensures that CELSIUS refuses to operate if the
licence file has been al-
tered. Without a valid
licence file in the CELSIUS base folder CELSIUS operates in the standard
version (not FDA-version) .
Once the programme has started, the
start screen appears. Confirm the
infobox (3) with
license information by clicking on "OK".
The
main programme window of CELSIUS is divided into the following areas:
1
2
4
3
5
6
7
1
Menu bar: The various processing options are given here (description from page
13
).
13 ).13
2
Toolbar: This contains buttons to quickly access the main functions
(for an explanation, see page
Toolbar: This contains buttons to quickly access the main functions
(for an explanation, see page
Toolbar: This contains buttons to quickly access the main functions
19
).
19 ).19
3 Information box
4 Main window: When functions have been run, you can create and edit tempering profiles
here (in graphical or tabular form, see page
4 Main window: When functions have been run, you can create and edit tempering profiles
here (in graphical or tabular form, see page
4 Main window: When functions have been run, you can create and edit tempering profiles
27
here (in graphical or tabular form, see page 27here (in graphical or tabular form, see page
and display logs (see page
4 Main window: When functions have been run, you can create and edit tempering profiles
and display logs (see page
4 Main window: When functions have been run, you can create and edit tempering profiles
27 and display logs (see page 27
38
).
38 ).38
5
Status line: A help text for the function currently chosen is displayed here, along with vari-
ous information on the current PC configuration.
Status line: A help text for the function currently chosen is displayed here, along with vari-
ous information on the current PC configuration.
Status line: A help text for the function currently chosen is displayed here, along with vari-
6 Licence number under which the software is registered
7 List of oven types and serial numbers for which this CELSIUS FDA licence can be used