Specifications
True Scale Fabric OFED+ Host Software
February 2014 RN 7.2.2.0.8
Order Number: H31512002US 23
OFED+ Host SW
IFS/
Open SM
Minor
When using opensm, after bouncing ports on a node, the port
may not return to an active state for a period of time. As a
result, commands that issue an SA query such as OFED's
saquery command, or various FastFabric tools such as
iba_report and iba_saquery, may hang waiting for the port to
become active and the SA to respond.
Restart opensm.
Intel recommends using the Intel
®
Fabric Manager, which has
much greater resiliency and quicker handling of port state
changes.
IFS/
IPoIB
NEW
Minor
When using vFabric to change an IPoIB application from
Networking to Non-Networking, the IPoIB interface may remain
in a running state.
After changing the application, restart the network services or
bring the interface down/up to force IPoIB to re-query the SM
and correct the situation.
IFS/
MPI2
NEW
Minor
When trying to rebuild mvapich2-1.6-qlc (PSM) with PGI 11.7,
it fails with the following error message:
configure: error: cannot run C compiled
programs
Add the following line to the login scripts, in the environment
such that is it available for both interactive and non-interactive
logins.
export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:$PGI/l
inux86-64/11.7/libso
After making the change to the login scripts, exit and log back
into the server so its defined and then run the do_*_build
script.
IFS/
Rolls/Kits
Minor
When using the Platform HPC and installing the Intel OFED+ or
IFS kits, some messages appear in the system log file regarding
unknown symbol and symbol version disagreement. These are
due to the way and order in which the Intel OFED+ or IFS kits
are installed and are resolved by the time OFED is started.
None
IFS/
Rolls/Kits
Minor
When the IFS is uninstalled and then reinstalled, some
messages appear in Platform HPC's CFM log about issues with
dependency resolution. These issues do not affect the operation
of any IFS utilities including FastFabric and Fabric Manager.
None
Table 11. Open Issues (Continued)
Product/
Component
Severity Description Workaround