Technical data
68
Perform each of the following tasks in order.
1. Choose the applicable task to remove the controller canisters:
— Remove the HIC from the E2612 or E2624 controller-drive tray.
— Remove the HIC from the E2660 controller-drive tray.
The remaining tasks in this section are the same for the E2612, E2624, and
E2660 controller-drive trays.
2. Install the HIC in the E2600 controller-drive tray.
ATTENTION Possible hardware damage – If you perform this procedure with the
power turned on, the equipment might overheat if the controller slot is left open for
more than three minutes. To prevent the possibility of overheating, you must insert the
controller air blocker into the controller slot when servicing the controller.
Removing the Host
Interface Card from
the E2612 or E2624
Controller-Drive Tray
To install a new host interface card (HIC), you must first remove the controller
canister.
NOTE Before you remove the controller canisters, make sure that you set controller
A offline, as described in the following steps, to make sure that all the data currently
in the cache in controller A is successfully written to disk before the upgrade. This step
also makes sure that the data currently in the cache in controller B is successfully
written to disk before you turn off the power to both of the controller canisters.
ATT ENTIO N Possible hardware damage – To prevent electrostatic discharge damage
to the tray, use proper antistatic protection when handling tray components.
1. Gather support data about your storage array by using one of these methods:
2. Put on antistatic protection.
SANtricity ES From the Array Management Window toolbar, select
Monitor >> Health >> Collect Support Data. Then
name and specify a location on your system where
you want to store the support bundle.
Command line interface Enter the following command on the command line:
save storageArray supportData
This command gathers comprehensive support data
about the storage array. For more information about
this command, refer to Command Line Interface and
Script Commands Programming Guide. Running this
command can temporarily impact performance on
your storage array.