Technical data

58
Figure 42 Controller LEDs
1. Host Link 1 Service Action Required LED (Green)
2. Host Link 2 Service Action Required LED (Green)
3. Battery Service Action Required LED (Amber)
4. Controller Service Action Allowed LED (Blue)
5. Controller Service Action Required LED (Amber)
4. Based on the LED status, perform one of these actions:
All of the Service Action Required LEDs are off, and the Array
Management Window indicates an Optimal status – Go to step 11.
Any of the controller-drive tray’s Service Action Required LEDs are on,
or the Controller Service Action Required LED is on – Go to step 5.
5. Based on the Recovery Guru display, perform one of the following actions:
The Recovery Guru displays the following message:
REC_CACHE_BACKUP_DEVICE_INSUFFICIENT_CAPACITY – The
controllers might require an additional power cycle to initialize the new
cache backup memory devices. Turn off the Power switches on both
controller canisters. Wait until all LED and seven-segment display activity
has stopped, and then turn on the Power switches on both power-fan
canisters. Go to 6.
The Recovery Guru does not display an insufficient capacity message
Check that the controller canister has been installed correctly. Reinstall the
controller canister if necessary. Go to step 10.
6. Did this action correct the problem?
Yes – Go to step 11.
No – If the problem is not resolved, contact your Technical Support
representative.
7. Using the LEDs and the storage management software, check the status of the
trays in the storage array.
8. Does any component have a Needs Attention status?
Yes – Click the Recovery Guru toolbar button in the Array Management
Window, and complete the recovery procedure. If the problem is not
resolved, contact your Technical Support representative.
No – Go to step 13.