Data Sheet
MLX90614 family
Single and Dual Zone
Infra Red Thermometer in TO-39
8.4.7.2 Exit from Sleep Mode
Sleep
Awake Normal
SCL
PWM/SDA
tDDq
Figure 10: Exit Sleep Mode
First data is available 0.2 seconds (typ) after exit from Sleep is done. On-chip IIR filter is skipped for the very
first measurement. All measurements afterwards pass the embedded digital filtering as configured in
EEPROM. Details on embedded filtering are available in application note “Understanding MLX90614 on-chip
digital signal filters”, available from www.melexis.com
3901090614 Page 19 of 42 Data Sheet
Rev 004 30/Jul2008