Specifications
Picker Solenoid Assembly
This assembly is mounted under the embroidery head in the rear bed. To remove
this assembly refer to the following steps:
1. Remove the left rear table top (with optional bobbin winder assembly).
2. Loosen the nut securing the solenoid to the bracket under the trimmer assembly
and allow the solenoid to drop off the bracket.
CAUTION! Use care not to loose the solenoid return spring in the
next step.
3. At the solenoid plunger, loosen the set screw in the picker swivel clamp and
remove the picker wire from the end of the plunger.
4. Remove the old solenoid wires from the main connector and transfer the new
solenoid wires into the same positions in the connector.
5. Transfer the solenoid return spring from the old solenoid to the new one and
reattach the picker wire at the end of the solenoid plunger.
6. Position the new solenoid in the bracket and secure it with the nut.
7. Reinstall the left rear table top (with optional bobbin winder assembly).
8. Refer to the procedure for adjusting the picker when you have finished the
installation.
Home Position Optical Switch
1. Remove the cap head screw holding the body of the optical switch in position
(see Figure 4-3).
2. Carefully manipulate the switch harness through the cutout in the bracket until
you can access and disconnect the in-line connector.
3. Connect the new optical switch to the in-line connector and place the switch in
position on the bracket.
4. Reconnect the optical switch with the cap head screw.
Picker Assembly
1. Disconnect the picker link from the picker base by loosening the set screw inside
the swivel pivot of the picker base (see Figure 4-4).
2. Remove the external retaining ring at right end of the picker base shaft.
4 - 6 Trimmer Replacement Procedures
EMT 10T Technical Manual Melco Embroidery Systems