Specifications

Thread Tensioner Assembly
Assembly Removal
1. Turn OFF the EMT 10T and disconnect the power cord from its power source.
2. Remove the three screws and any ground wire; then remove the cover from the
left side of the thread tensioner assembly shown in Figure 3-6.
3. Remove the two screws and the thread tube retaining bracket from the top of
the right side tensioner cover.
4. Remove the two screws and the right side tensioner cover.
5. Remove the retainer bar holding the ribbon cable at the rear of the tensioner PCB
and disconnect the ribbon cable connection at the PCB.
6. Remove the 4 screws at the front of the tensioner assembly shown in Figure 3-7,
then carefully lay the tensioner bracket assembly (with the thread tubes still
attached) over the top of the thread tree.
tensioner cover
(right side)
tensioner
cover
(left side)
thread
tensioner
assembly
ground wire
Figure 3 - 6
thread tensioner
assembly
4 screws
Figure 3 - 7
Assembly Removal 3 - 9
110291-01, Rev D 3. Embroidery Head Maintenance