Specifications
Power Distribution Section
The AC voltage distribution panel, power supplies, and associated circuitry for the
EMT 10/4T are located inside the left chassis leg. In addition to the AC voltage
distribution panel, there are two power supplies, one for logic voltages and another
for motors, and the e-stop control PCB located in this section.
AC Input Voltage Selection
1. Refer to Figure 2-22 and unplug the main power cord at the entry module on the
AC voltage distribution panel inside the left frame leg.
2. Locate the voltage selector switch on the AC voltage distribution panel.
CAUTION! Be Certain Power Is NOT Applied To The Peripheral When
Performing The Next Step.
3. Slide the voltage selector switch to the appropriate position: 115 Volts or 230
Volts, depending on your input voltage.
4. Squeeze the tabs on either side of the fuse holder built into the entry module
and remove the fuse holder and fuses.
5. Place the correct fuses in the fuse holder, depending on the selected voltage and
the following fuse value:
115 Volt Source selected - 10 Amp Fuses
230 Volt Source selected - 5 Amp Fuses
AC VOLTAGE DISTRIBUTION PANEL
voltage
selector switch
main power
cord entry module
Figure 2 - 22
2 - 30 Power Distribution Section
EMT 10/4T Technical Manual Melco Embroidery Systems