Specifications

8. Place the UTC assembly under the needle plate support bracket as shown in
Figure 4-25 and install the 2 UTC assembly mounting screws.
9. Perform the UTC adjustments.
UTC assembly
and rotary hook
retaining finger
needle plate
support
bracket
UTC assembly
mounting screws
Figure 25
4 - 30 Under Thread Control (UTC) Replacement
EMT 10/4T Technical Manual Melco Embroidery Systems