Specifications

Y Motor Belt Tension
Note: This procedure requires the use of a special service tool: a 0 to 40 pound
pull gauge.
1. Loosen the 4 Y motor socket head cap screws enough for the motor to move on
the motor bracket. (Refer to Figure 2-7.)
2. Wrap a piece of small, strong cable or cord around the Y motor drive pulley of
the side nearest the motor.
3. Form loops in the ends of the cable or cord and hook a 0 to 40 pound pull
gauge into the loops.
4. Pull straight down on the pull gauge until it reads 30 pounds.
5. While holding the pull gauge at the 30 pound reading, tighten the 4 motor
socket head cap screws to secure the motor with the belt tensioned at 30
pounds of pull.
6. Remove the cable or cord.
AC Input Voltage Selection
Locate the power distribution assembly inside the right chassis support leg. Slide
the voltage selector switch to one of two positions: 115 volts or 220 volts,
depending on your input voltage.
Voltage
Selector
Switch
Fuses
located
behind
this cover
Main Power
Input Cord
installs here
power distribution assembly located
inside right chassis support leg
Figure 2 - 8
AC Input Voltage Selection 2 - 9
110305-01, Rev A 2. Service Adjustments