Specifications
Under Carriage Section
This section is physically located in and about the peripheral support framework. The
X and Y motors are attached under the embroidery head platform, and the power
supply and motor drivers are found inside the frame support legs at either end.
X Motor Belt Tension
Note: This procedure requires using a 0 to 40 pound special service tool pull gauge.
1. Loosen the 4 X motor socket head cap screws enough for the motor to move on
the motor bracket. (Refer to Figure 2-7.)
2. Wrap a piece of small, strong cable or cord around the X motor drive pulley to
the side nearest the motor.
3. Form loops in the ends of the cable or cord and hook a 0 to 40 pound pull
gauge into the loops.
4. Pull straight down on the pull gauge until it reads 30 pounds.
5. While holding the pull gauge at the 30 pound reading, tighten the 4 motor
socket head cap screws to secure the motor with the belt tensioned at 30
pounds of pull.
6. Remove the cable or cord.
socket head
cap screws
(2 of 4)
0-40 pound
pull gauge
X Drive
Motor
cable
or cord
motor
pulley
Illustration shown tensioning the
X motor belt only. The setup for
the Y motor belt will be identical
except on the Y motor.
Y Drive
Motor
motor
belt
Figure 2 - 7
2 - 8 Under Carriage Section
EMC 10/4 Technical Manual Melco Embroidery Systems