Specifications
10. Refer to the following X Drive Belt Tension procedure to retension the belt.
X Drive Belt Tension
"FACTORY SERVICE ADVISED"
Note: This procedure requires using a special service tool: the X-Belt Fixture, part
number 995509-01.
1. Turn OFF the embroidery peripheral and unplug the power cord.
2. Remove the table top inserts and the middle table top section.
3. Position the X carriage to the center of the embroidery field by centering one of
the threaded inserts on the bottom of the carriage over the center of the
embroidery head bed covers as shown in Figure 2-5.
4. Check the set home position and adjust if required by referring to the previous
procedure.
5. Inspect the two X carriage belt ends under the carriage assembly (see Figure 2-4).
The clamps at each end should be the same distance from the socket head cap
screw mounts.
6. Loosen the 2 phillips head screws that secure the X carriage belt clamps to the X
carriage at both ends of the X carriage belt (see Figure 2-4).
right side of the
Most Forward
Disk protruding
the same amount
as the left side
left side of the
Most Forward Disk
protruding the
same amount as
the right side
Front Support Bracket
Figure 2 - 3
X Drive Belt Tension 2 - 5
110305-01, Rev A 2. Service Adjustments