Specifications

The second configuration item is the network address (or Unit Number). The Unit
Number must be set and be different for each peripheral attached to an EDS II or
EDS III computer or network. There may be up to 64 (16 if using EDS II software)
total embroidery peripherals attached to any one computer, and each must have its
own Unit Number. The number is selected from the peripheral Keyboard and is
between 1 and 64 (16 if using EDS II software).
The third and last configuration item is to choose if you want the Display
Language
to appear in English or Spanish.
The ‘‘configuration mode’’ in the EMC 10/4 is accessible by pressing a certain
keystroke combination while switching ON the power. When the EMC 10/4 is
initially turned ON, and any time you wish to change the configuration status of the
machine, refer to the following steps:
NOTE: If the Peripheral Program has not been downloaded (the program
and unit number alternately show on the display), you can also enter into
the configuration mode without turning the machine OFF, then ON again.
Configuration Procedure
1. Before you turn ON the EMC 10/4 (or if the unit has not yet been
"downloaded"), locate the 10-key keyboard at the front of the peripheral unit,
between heads #2 and #3.
2. Also locate the power switch at the right end of the unit (see Figure 1-2).
3. Turn ON the EMC 10/4 by moving the power switch to the ON position; and
within 5 seconds, press and hold the 3 keys ON the peripheral keyboard marked:
, , and .
4. Hold these keys depressed until the unit ‘‘beeps’’ and the display shows a
message depicting the Peripheral Program currently selected.
Power
Switch
Figure 1 - 2
1 - 6 System Overview
EMC 10/4 Technical Manual Melco Embroidery Systems