Specifications

Home Position Optical Switch
1. Remove the cap head screw holding the body of the optical switch in position
(see Figure 3-42).
2. Carefully manipulate the switch harness through the cutout in the bracket until
you can access and disconnect the in-line connector.
3. Connect the new optical switch to the in-line connector and place the switch in
position on the bracket.
4. Reconnect the optical switch with the cap head screw.
Picker Assembly
1. Remove the screws holding the needle plate. Remove the needle plate.
2. Disconnect the picker link from the picker base by loosening the set screw inside
the swivel pivot of the picker base (see Figure 3-43).
3. Remove the external retaining ring at right end of the picker base shaft.
4. Slide the picker assembly out of the picker bracket mount.
When re-attaching the picker link to the picker assembly, refer to the alignment
section of this manual for the alignment procedure for the picker position.
mounting
screws
Picker
Bracket
Mount
Picker
Picker Link
Swivel Pivot
set screw
External
Retaining
Ring
Picker
Base and
shaft
Figure 3 - 43
3 - 50 Head Section
EMC 10/4 Technical Manual Melco Embroidery Systems