Specifications

Trimmer Drive Assembly
Trimmer Cam
FACTORY SERVICE ADVISED!
This assembly is mounted under the head in the rear bed. To remove this
mechanical assembly requires several steps, including removing the embroidery
head from the frame. A factory trained technician is recommended for removal and
installation of parts in this area.
Trimmer Solenoid
NOTE; When the trimmer solenoid mount is moved, the movable knife home
position may become mis-adjusted. Refer to the movable knife home
position adjustment procedure after the solenoid is reinstalled.
1. Remove the head rear bed cover to gain access to the trimmer drive assembly.
2. Refer to Figure 3-42 and mark the position of the solenoid mount in its track on
the movable frame. This will aid in returning the assembly to its current
position, helping to keep the movable knife home position as close as possible.
3. Remove the socket head cap screw from the solenoid mount and lift the solenoid
and mount out together.
4. Loosen the set screw in the top of the solenoid mount to allow the solenoid to
be rotate out of the mount.
hex nut between
solenoid and mount
cap
head
screw
trimmer solenoid
mark solenoid
mount position
solenoid mount
socket head cap screw
optical
switch
set screw in top of
solenoid mount
Figure 3 - 42 Trimmer Camming Mechanism
3 - 48 Head Section
EMC 10/4 Technical Manual Melco Embroidery Systems