P=5, Output5.
F=0, to close the output (open drain);
F=1, to open the output (low voltage).
Example: W000000,020,1,1
15.2 Output Control (Conditional)
Command: W******,120,ABCDE or W******,220,ABCDE
Description: Send this command to control the Output of VT310. This command is only workable when the speed is below
10km/h(command 120) or 20km/h(command 220) and GPS is available.
Note:
ABCDE represents Out1, Out2, Out3, Out4, and Out5 respectively.
If A or B or C or D or E,
=0, to close the output (open drain);
=1, to open the output (low voltage);
=2, to remain previous status.
Example:
W000000,120,10000
W000000,220,10000
15.3 Application Examples for Outputs
15.3.1 Engine Cut
Relay Connection: Connect a relay as below picture shows:
Calculate the correct VCC value according to relay’s parameter to comply with the following requirements:
Output open drain sink voltage (ineffective) 45V max
Output Low voltage sink current (effective) 500mA max