4.7. Default Alarm Thresholds
To change a modules Alarm Threshold from their default settings, log into the appropriate chassis and using the GUI click on
the image of the module you desire to change. This will bring you to the parameters page for that particular module. From
here, a simple click on the Analog tab at the top of the webpage (or clicking the Analog hyperlink under properties) will bring
you to the webpage where you can edit the Alarm Thresholds for that module type. If changes are made, be sure to click
“save changes” before leaving the webpage.
*- Denotes optional “F” version
**- Denotes laser value
4-6 MAXNET
®
II – MP3 Active / Passive Chassis – Installation & Operation Manual
CHAPTER 4: STATUS MONITORING
Common Default Alarm Thresholds
HMS MIB Variable GUI Reference LOLO LO HI HIHI
hePsOutputVoltage Voltage Out (V) 220 220 260 260
heCommonTemperature Temperature (C) -400 -400 850 850
hePsOutputCurrent Current Out (mA) 0 0 11000 11000
hePsOutputPower Power Out (mW) 0 0 26000 26000
Transmitter (MPTX4*-**, MPTX8*-**) Default Alarm Thresholds
HMS MIB Variable GUI Reference LOLO LO HI HIHI
heOpTxLaserTemp OptTx Laser Temperature (C)
0 0 400 400
heOpTxLaserBiasCurrent OptTx Laser Bias Current (mA)
0 0 1000 1000
heOpTxLaserOutputPower OptTx Laser Output Power (dBm)
0 0 160 160
AmplierDefaultAlarmThresholds
HMS MIB Variable GUI Reference LOLO LO HI HIHI
heRFAmpOutputLevel
RF Amp Output Level (dBmV)
300 300 750 750
Receiver (MPRX8*, MPRXRR, MPRX2-4*) Default Alarm Thresholds
HMS MIB Variable GUI Reference LOLO LO HI HIHI
heOpRxInputPower
OptRx Input Power (dBm)
-170 -170 30 30