Technical information

SNMP branch Variable Data type Description
mbgLtCfgNtpServer3KEY integer Link to the key which should be used
for the third NTP-server
mbgLtCfgStratumLocalClock integer(0..15) Stratum-value of the internal system
clock of the timeserver
mbgLtCfgNTPTrustedKey integer Link to the key which should be used
for the internal reference time source
mbgLtCfgNTPBroadcastIP string (IPv4 or IPv6-
address)
IP-address, which has to be used for
NTP-broadcasts (or multicasts)
mbgLtCfgNTPBroadcastKey integer Link to the key which should be used
for outgoing NTP-broadcasts
mbgLtCfgNTPBroadcastAutokey integer (0 =
disabled, 1 =
enabled)
Use autokey for NTP broadcasts?
mbgLtCfgAutokeyFeature integer (0 =
disabled, 1 =
enabled)
Use autokey feature of the NTP server?
mbgLtCfgAtomPPS integer (0 =
disabled, 1 =
enabled)
Atom PPS (pulse per second) activated?
mbgLtCfgEMail mbgLtCfgEMailTo string (Liste von
EMail-addressn)
One or more (semicolon separated)
email address(es). which should receive
warnings and alarm notifications from
the timeserver
mbgLtCfgEMailFrom string (EMail-
address)
The EMail-address which is used as the
senders address for email notifcations
mbgLtCfgEMailSmarthost string (IPv4 or IPv6-
address or
hostname)
The SMTP-host, which is used for
sending mails
mbgLtCfgSNMP mbgLtCfgSNMPTrapReceiver1 string (IPv4 or IPv6-
address or
hostname)
First host, which receives notifications
sent as SMTP-traps
mbgLtCfgSNMPTrapReceiver1Commu
nity
string The SNMP community used when
sending SNMP-Traps to the first host
mbgLtCfgSNMPTrapReceiver2 string (IPv4 or IPv6-
address or
hostname)
Second host, which receives
notifications sent as SMTP-traps
mbgLtCfgSNMPTrapReceiver2Commu
nity
string The SNMP community used when
sending SNMP-Traps to the second host
mbgLtCfgSNMPROCommunity string The SNMP community, which has read-
only access and therefore can be used to
only monitor status variables or
configuration values (SNMP V2c)
mbgLtCfgSNMPRWCommunity string The SNMP community, which has read-
write access and there for can be used to
monitor status variables and get/set
configuration values (SNMP V2c)
mbgLtCfgSNMPContact string Contact information (e.g. name of a
contact person) of the timeserver
mbgLtCfgSNMPLocation string Location (e.g. building/room number) of
the timeserver
mbgLtCfgWinpopup mbgLtCfgWMailAddress1 string First receiver of notifications sent as
windows popup messages
mbgLtCfgWMailAddress2 string Second receiver of notifications sent as
windows popup messages
mbgLtCfgWalldisplay mbgLtCfgVP100Display1IP string (IPv4 or IPv6-
address or
hostname)
hostname or IP-address of the first
wallmount display used for showing
notifications
mbgLtCfgVP100Display1SN string (Hexstring) The serial number of the first wall
mount display used for showing
notifications (can be found in the setup
menu of the display)
mbgLtCfgVP100Display2IP string (IPv4 or IPv6-
address or
hostname)
hostname or IP-address of the second
wall mount display used for showing
notifications
mbgLtCfgVP100Display2SN string (Hexstring) The serial number of the first wall
mount display used for showing
notifications (can be found in the setup
menu of the display)
107