Manual
17.  Specification
Input voltage Up to 250 V (single phase system) / up to 430 V (three phase 
system),
Input Frequency 50/60 Hz,
Type 2 to Type 1 Adaptor Type 1 AC charging mode 3, suitable to IEC 62196-2 type 1 or 
SAE J1772 with vehicle connector (Type 1, 5P single-phase)
Type 2 Charging Plug Type 2 AC charging mode 3, suitable to IEC 62196-2 type 2 
socket outlet or fixed cable with vehicle connector (Type 2, 7P 
three-phase)
PE Pre-Test  Yes - Button
PP Simulation  NC, 13 A, 20 A, 32 A, 63 A
CP States  A, B, C, D
CP Error “E”  Yes
PE Error (Earth fault)  Yes
Measuring Ports Max. 250/430 V AC, CAT II 250 V, max. 10 A 
L1, L2, L3, N and PE 
Mains socket  Max. 250 V AC, CAT II 250 V, max. 10 A,
Note: Do not load mains socket simultaneously with measuring ports!
CP Signal output Ports Approx. +/-12 V, CAT 0 (under normal condition)
Measurement category  CAT II 250 V
Altitude above sea level. 2000 m max.
Dimensions (W × H × L)  109 mm x 227 mm x 63 mm (without connection cable and 
test cable)
Weight  Approx: 780 g
CE directive  Low Voltage Directive LVD 2014/35/EU 
Safety  IEC/EN 61010-1:2010 IEC/EN 61010-2-030:2010
Working temperature  0 °C to +40 °C
Storage temperature  -10 °C to +50 °C
Working humidity  10 % to 85% relative humidity w/o condensation
Fuse Rating Ceramic 10 A/250 V (5 mm x 20 mm)
Product manufactured in China
18.  Maintenance
Do not open the adapter case. It contains no user-serviceable parts. Repair or servicing should be 
performed only by qualified personnel.
www.megger.com
EVCA210 
14
Specification